7-7
VLT is a registered Danfoss trademark
Figure 7-8. SCR and Diode Modules (1 of 3)
5.
Remove wire retaining nut (8 mm) from SCR
output bus bars (BB42). One from (+) DC bus bar
and one from (–) DC bus bar.
6.
Note color coding for each wire attached to
retaining studs. Ensure that correct wire is
attached to applicable stud upon reassembly.
Remove wiring from studs.
7.
Remove 4 retaining nuts (13 mm) on side of bus
bars, 2 on each bus bar.
CONTINUED NEXT PAGE
7.10 SCR and Diode Modules
1.
Remove lower DC capacitor bank in accordance
with procedure.
2.
Remove input terminal plate in accordance with
procedure.
3.
Remove wire retaining nut (10 mm) from each of
3 SCR input bus bars (BB41).
4.
Note color coding for each of 3 wires attached to
retaining studs. Ensure that correct wire is
attached to applicable stud upon reassembly.
Remove wiring from studs.
SCR module
Wire retaining nut on
bus bar BB41 (Step 3)
Diode module
Wire retaining nuts for
output bus bars BB42
(Steps 5 & 6)
Retaining nuts
(Step 7)
Summary of Contents for VLT series
Page 1: ...MOTION CONTROLS Service Manual VLT 4152 4652 VLT 5122 5602 VLT 6152 6652 VLT 8152 8652...
Page 8: ......
Page 20: ......
Page 32: ......
Page 41: ...2 9 VLT is a registered Danfoss trademark Figure 2 7 Inverter Section...
Page 58: ......
Page 96: ......
Page 152: ......