![Danfoss VLT series Service Manual Download Page 116](http://html1.mh-extra.com/html/danfoss/vlt-series/vlt-series_service-manual_3686139116.webp)
6-20
VLT is a registered Danfoss trademark
Figure 6-13. Fan Assembly (2 of 2)
Inline molex connector (Step 6)
Retaining nut (Step 7)
5.
Disconnect in-line molex connector.
6.
Remove fan assy by removing 6 (8mm) retaining
nuts from stud. Note that fan assy weighs approx.
18 lbs (8 kg).
Reinstall in reverse order of this procedure. Tighten mounting
nuts to 20 in-lbs (2.25 Nm).