VLT
®
FCD Series
Basic standard
Burst
61000-4-4
Surge
61000-4-5
ESD
61000-4-2
Radiated
61000-4-3
Mains
distortion
VDE 0160
RF cm
voltage
2
61000-4-6
Acceptance
criterion
B
B
B
A
A
Port connection
CM
DM / CM
Field
DM
CM
Line
OK / OK
OK
Motor
OK
Control lines
OK
- / OK
1
OK
Relay
OK
- / OK
OK
Profibus
OK
- / OK
1
OK
Signal interface
<3 m
OK
Enclosure
OK
OK
Standard bus
OK
- / OK
1
OK
Basic speci-
fications
Line
2 kV / DCN
2 kV / 4kV
10 Vrms
Motor
10 Vrms
Control lines
2 kV / CCC
2 kV/2
1
10 Vrms
Relay
2 kV / CCC
2 kV/2
1
10 Vrms
Profibus
2 kV / CCC
2 kV/2
1
10 Vrms
Signal interface
<3 m
2 kV / CCC
Enclosure
8 kV AD
6 kV CD
10 V/m
Standard bus
2 kV / CCC
2 kV/2
1
10 Vrms
DM: Differential mode
CM: Common mode
CCC: Capacitive clamp coupling (5 kHz)
DCN: Direct coupling network (5 kHz)
1. Injection on cable shield.
2. Electromagnetic clamp.
MG.04.A1.02 - VLT is a registered Danfoss trade mark