VLT
®
FCD Series
PNU
#
Parameter
description
Factory setting
4-setup
Conv.
index
Data
type
600
Operating hours
No
73
7
601
Hours run
No
73
7
602
kWh counter
No
2
7
603
Number of cut ins
No
0
6
604
Number of overtemperatures
No
0
6
605
Number of overvoltages
No
0
6
615
Fault log: Error code
No
0
5
616
Fault log: Time
No
0
7
617
Fault log: Value
No
0
3
618
Reset of kWh counter
No reset
No
0
7
619
Reset of running hours counter
No reset
No
0
5
620
Operation mode
Normal operation
No
0
5
621
Nameplate: Unit type
No
0
9
624
Nameplate: Software version
No
0
9
625
Nameplate: LCP identification no.
No
0
9
626
Nameplate: Database identification no.
No
-2
9
627
Nameplate: Power parts version
No
0
9
628
Nameplate: Application option type
No
0
9
630
Nameplate: Communication option type
No
0
9
632
Nameplate: BMC software identification
No
0
9
633
Nameplate: Motor database identification
No
0
9
634
Nameplate: Unit identification for communication
No
0
9
635
Nameplate: Software parts no.
No
0
9
640
Software version
No
-2
6
641
BMC software identification
No
-2
6
642
Power card identification
No
-2
6
678
Configure Control Card
No
0
5
4-Setup:
’Yes’ means that the parameter can be programmed
individually in each of the four Setups, i.e. one sin-
gle parameter can have four different data values.
No’ means that the data value will be the same in all
Setups.
Conversion index:
This number refers to a conversion figure to be used
when writing or reading via serial communication
with a frequency converter.
See
Data character
in
Serial communication.
Data type:
Data type shows the type and length of the telegram.
Data type
Description
3
Integer 16
4
Integer 32
5
Unsigned 8
6
Unsigned 16
7
Unsigned 32
9
Text string
MG.04.A1.02 - VLT is a registered Danfoss trade mark