N250
N315
N400
P450
P500
P560
P630
Normal Load*
NO
NO
NO
NO
NO
NO
NO
Typical Shaft output at 550 V [kW]
200
250
315
355
400
450
500
Typical Shaft output at 575 V [hp]
300
350
400
450
500
600
650
Typical Shaft ouTput at 690 V [kW]
250
315
400
450
500
560
630
Enclosure IP21
D2h
D2h
D2h
E1
E1
E1
E1
Enclosure IP54
D2h
D2h
D2h
E1
E1
E1
E1
Enclosure IP20
D4h
D4h
D4h
-
-
-
-
Enclosure IP00
-
-
-
E2
E2
E2
E2
Output current
Continuous (at 550 V) [A]
303
360
418
470
523
596
630
Intermittent (60 s overload) (at 550 V)[A]
333
396
460
517
575
656
693
Continuous (at 575/690 V) [A]
290
344
400
450
500
570
630
Intermittent (60 s overload) (at 575/690 V) [kVA]
319
378
440
495
550
627
693
Continuous kVA (at 550 V) [kVA]
289
343
398
448
498
568
600
Continuous kVA (at 575 V) [kVA]
289
343
398
448
498
568
627
Continuous kVA (at 690 V) [kVA]
347
411
478
538
598
681
753
Max. Input current
Continuous (at 550 V) [A]
299
355
408
453
504
574
607
Continuous (at 575 V) [A]
286
339
390
434
482
549
607
Continuous (at 690 V) [A]
296
352
400
434
482
549
607
Max. cable size: mains, motor and load share, mm
(AWG)
2x185 (2x350 mcm)
4x240
(4x500
mcm)
Max. cable size: brake, mm (AWG)
2x185 (2x350 mcm)
Max. external mains fuses [A]
400
500
550
700
700
900
900
Estimated power loss at 575 V [W]
3719
4460
5023
5323
6010
7395
8209
Estimated power loss at 690 V [W]
3848
4610
5150
5529
6239
7653
8495
Weight, enclosure IP21, IP54 kg (lbs.)
125 (275)
Weight, enclosure IP20 kg (lbs.)
125 (275)
-
Weight, enclosure IP00 kg (lbs.)
-
221 (487)
221 (487)
236 (520)
277 (611)
Efficiency
0.98
Output frequency [Hz]
0-590
0-525
Heatsink overtemp. trip [
°
C]
110
95
110
Power card ambient trip [
°
C]
80
85
*Normal overload=110% current for 60 s
Table 11.3 Mains Supply 3x525-690 V AC
•
The typical power loss is at nominal load conditions and expected to be within
±
15% (tolerance relates to variety
in voltage and cable conditions).
•
The losses are based on the default switching frequency. The losses increase significantly at higher switching
frequencies.
Specifications
Operating Instructions
MG16J202
Danfoss A/S © Rev. 05/2014 All rights reserved.
97
11
11
Summary of Contents for VLT FC 103
Page 2: ......