VLT
®
8000 AQUA
All about VLT 8000
AQUA
■
Factory settings
PNU
#
Parameter
description
Factory setting
Range
Changes
during
opera-
tion
4-setup Con-
ver-
sion
index
Data
type
500
Protocol
FC
Yes
Yes
0
5
501
Address
001
Depends on
par.500
Yes
No
0
5
502
Baudrate
9600 BAUD
Yes
No
0
5
503
Coasting
LOGIC OR
Yes
Yes
0
5
504
DC-brake
LOGIC OR
Yes
Yes
0
5
506
Start
LOGIC OR
Yes
Yes
0
5
506
Reversing
DIGITAL INPUT
Yes
Yes
0
5
507
Selection of Setup
LOGIC OR
Yes
Yes
0
5
508
Selection of Preset Reference
LOGIC OR
Yes
Yes
0
5
509
Data Read-out: Reference %
No
No
-1
3
510
Data Read-out: Reference Unit
No
No
-3
4
511
Data Read-out: Feedback
No
No
-3
4
512
Data Read-out: Frequency
No
No
-1
6
513
User Defined Read-out
No
No
-2
7
514
Data Read-out: Current
No
No
-2
7
515
Data Read-out: Power, kW
No
No
1
7
516
Data Read-out: Power, HP
No
No
-2
7
517
Data Read-out: Motor Voltage
No
No
-1
6
518
Data Read-out: DC Link Voltage
No
No
0
6
519
Data Read-out: Motor temp.
No
No
0
5
520
Data Read-out: VLT Temp.
No
No
0
5
521
Data Read-out: Digital Input
No
No
0
5
522
Data Read-out: Terminal 53, Analog Input
No
No
-1
3
523
Data Read-out: Terminal 54, Analog Input
No
No
-1
3
524
Data Read-out: Terminal 60 Analog Input
No
No
-4
3
525
Data Read-out: Pulse reference
No
No
-1
7
526
Data Read-out: External Reference %
No
No
-1
3
527
Data Read-out: Status Word, Hex
No
No
0
6
528
Data Read-out: Heat Sink Temperatur
No
No
0
5
529
Data Read-out: Alarm Word, Hex
No
No
0
7
530
Data Read-out: Control Word, Hex
No
No
0
6
531
Data Read-out: Warning Word, Hex
No
No
0
7
532
Data Read-out: Extended Status Word, Hex
No
No
0
7
533
Display Text 1
No
No
0
9
534
Display Text 2
No
No
0
9
535
Bus Feedback 1
00000
No
No
0
3
536
Bus Feedback 2
00000
No
No
0
3
537
Data Read-out: Relay Status
No
No
0
5
555
Bus Time Interval
60 sec.
1 to 99 sec.
Yes
Yes
0
5
556
Bus Time Interval Function
NO FUNCTION
Yes
Yes
0
5
570
Modbus parity and message framing
No parity
1 stopbit
Yes
Yes
0
5
571
Modbus communications timeout
100 ms
10-2000 ms
Yes
Yes
-3
6
MG.83.A2.02 - VLT is a registered Danfoss trademark