VLT® 5000 Crane
515-541 Data readout
Value:
Par.
no.
Description
Display text
Unit
Update
interval (ms)
515
Res. reference
(REFERENCE)
%
80
516
Res. reference [Unit]
(REFERENCE [UNIT])
Hz, RPM
80
517
Feedback [Unit]
(FEEDBACK [UNIT])
RPM
80
518
Frequency
(FREQUENCY)
Hz
80
519
Motor speed
(MOTOR SPEED)
RPM
80
520
Motor current
(MOTOR CURRENT)
Amp
80
521
Torque
(TORQUE)
%
80
522
Power[kW]
(POWER (KW))
kW
80
523
Power[HP]
(POWER (HP))
HP
80
524
Motor voltage
(MOTOR VOLTAGE)
V
80
525
DC link voltage
(DC LINK VOLTAGE)
V
80
526
Thermal load motor
(MOTOR THERMAL)
%
80
527
Thermal load inverter
(INV. THERMAL)
%
80
528
Digital input
(DIGITAL INPUT)
Bin
2
529
Term.53, analogue input
(ANALOG INPUT 53)
V
20
530
Term. 58, analogue input
(ANALOG INPUT 58)
V
20
531
Term.60, analogue input
(ANALOG INPUT 60)
mA
20
533
External ref.
(EXT. REFERENCE)
%
20
534
Status word, Hex
(STATUS WORD)
Hex
20 ms
537
Inverter temperature
(INVERTER TEMP.)
°C
1.2 sec
538
Alarm word
(ALARM WORD)
Hex
2 ms
539
Control word
(CONTROL WORD)
Hex
20 ms
540
Warning word
(WARN. WORD)
Hex
20ms
541
Extended status word
(STATUS WORD)
Hex
0
Function:
These parameters can be read out via the serial
communication port and the LCP display. See also
parameters 009-012
Display readout
.
Description of choice:
Resulting reference %, parameter 515:
Gives the resulting reference as a percentage in the
range from 0 to Maximum reference, Ref
MAX
.
Resulting reference [unit], parameter 516:
Gives the resulting reference in Hz in Open
loop (parameter 100). In Closed loop the
reference unit is in RPM.
Feedback [unit], parameter 517:
Gives the resulting feedback speed, see
also parameter 519.
Frequency [Hz], parameter 518:
Gives the output frequency from the
frequency converter.
Motor speed [RPM], parameter 519:
Corresponds to the present output speed.
Motor current [A], parameter 520:
Gives the motor
’
s phase current measured
as an effective value.
Torque [%], parameter 521:
Gives the motor
’
s present load in relation to
the motor
’
s rated torque.
Power [kW], parameter 522:
Gives the motor
’
s present power in kW which
the motor absorbs.
Power [HP], parameter 523:
Gives the motor
’
s present power in HP which
the motor absorbs.
Motor voltage, parameter 524:
Gives the voltage supplied to the motor.
DC link voltage, parameter 525:
Gives the intermediate circuit voltage in the
frequency converter.
✭
= factory setting. () = display text [] = value for use in communication via serial communication port
MG.50.N4.02 - VLT is a registered Danfoss trademark
84