![Danfoss VLT 2800 Series Operating Instructions Manual Download Page 16](http://html1.mh-extra.com/html/danfoss/vlt-2800-series/vlt-2800-series_operating-instructions-manual_3484328016.webp)
Shifting from
Local operation
to
Remote operation
in
parameter 002
Local/remote operation
, while this pa-
rameter has been set to
Remote operation
: The local
reference will be replaced by the remote-operated ref-
erence signal.
014
Local stop
(LOCAL STOP)
Value:
Not active (DISABLE)
[0]
Active (ENABLE)
[1]
Function:
In this parameter, the local [STOP]-key can be engag-
ed or disengaged on the control panel and on the LCP
control panel.
Description of choice:
If
Not active
[0] is selected in this parameter, the
[STOP]-key will be inactive.
NB!
If
Not active
[0] is selected, the motor can-
not be stopped by means of the [STOP]-
key.
015
Local jog
(LOCAL JOGGING)
Value:
Not active (DISABLE)
[0]
Active (ENABLE)
[1]
Function:
In this parameter, the jog function on the LCP control
panel can be engaged/disengaged.
Description of choice:
If
Not active
[0] is selected in this parameter, the [JOG]-
key will be inactive.
016
Local reversing
(LOCAL REVERSING)
Value:
Not active (DISABLE)
[0]
Active (ENABLE)
[1]
Function:
In this parameter you can select/deselect the reversing
function on the LCP control panel. The key can only
be used if parameter 002
Local/remote operation
is set
to
Local operation
[1] and parameter 013
Localcon-
trol
to
Local control, open loop
[1] or
Local control as
parameter 100
[3].
Description of choice:
If
Disable
[0] is selected in this parameter, the [FWD/
REV] key will be disabled. See also parameter 200
Output frequency range
.
017
Local reset of trip
(LOCAL RESET)
Value:
Not active (DISABLE)
[0]
Active (ENABLE)
[1]
Function:
In this parameter, the reset function on the control
panel can be engaged/disengaged.
Description of choice:
If
Not active
[0] is selected in this parameter, the reset
function will be inactive.
NB!
Select
Not active
[0], only if an external
reset signal has been connected via the
digital inputs.
VLT
®
2800 Series
= factory setting, () = display text, [] = value for use in communication via serial communication port
MG.27.A2.02 - VLT
®
is a registered Danfoss trademark
15
Programming
Summary of Contents for VLT 2800 Series
Page 1: ...VLT 2800 MG27A202 VLT 2800 Operating Instructions Operating Instructions...
Page 62: ...192H4893 VLT 2800 Series MG 27 A2 02 VLT is a registered Danfoss trademark 61 Installation...
Page 76: ...VLT 2800 Series MG 27 A2 02 VLT is a registered Danfoss trademark 75 All about VLT 2800...
Page 77: ...VLT 2800 Series 76 MG 27 A2 02 VLT is a registered Danfoss trademark...
Page 103: ......