Data sheet | MPE 70 Energy recovery device
29
180R9426 | AQ367027814446en-000801 | IOM MPE 70 | 08.2022
Technical specifications
MPE 70
MPE 70 with
IEC motor
Weight (dry)
kg
114
151
lb
251
333
Weight (operation with water)
kg
119
156
lb
262
344
Noise
Sound pressure level L
PA
1 m
10)
dB(A)
85
85
Footprint
Footprint (vertical position)
11)
0.175
1.9
Torque data
Max. allowable working torque
Nm
15
15
lbf-ft
11
11
Max. starting torque (stick/slip)
Nm
90
90
lbf-ft
66
66
Motor data
Nominal speed
rpm
970
Rated current at 400V
A
5.7
Motor size
kW
2.2
12)
Frame size
IEC
112
Poles
6
Rated motor torque at nominal speed
Nm
21.8
lbf-ft
16.07
Rated motor ambient temperature
12)
°C
40
°F
104
Motor insulation
Class
F/B
Motor degrees of protection
IP
55
Motor efficiency
%
84.3
Painting RAL9005
C3L
Variable Frequency Drive (VFD) data
13)
Must be able to operate at constant torque over the whole range of speeds.
Must be able to deliver start current of 23.5 A. For a Danfoss FC 51 micro drive a 7.5 kW drive is required to deliver
this current. If other drives are used make sure it can provide the start current required.
6)
Efficiency measured at 70 m
3
/h, balanced flow, 60
bar(g) on HP out. Power consumption of Motor
and Variable Frequency Drive included.
7)
Dependent on NaCI concentation.
8)
Please see section 7.5 filtration.
9)
Balanced flow: The mixing rate is defined at
balanced flow when HP-out is equal to LP-in.
10)
MPE 70 sound pressure level at 60 barg and max.
flow.
11)
Area recommended with IE3 motor
configurations (excl. of space to serviece MPE)
12)
For higher temperature contact Danfoss
13)
A special attention must be taken when selecting
the frequency drive. See Variable Frequency Data
comments in the table above.
1)
Max. allowable working pressure of continous
operation. For lower and higher pressure, please
contact Danfoss.
2)
Typical pressure level at start-up and permeate
flush.
3)
Intermittent pressure is acceptable for less than 10
minutes within a period of 6 hours.
4)
At system start-up: MPE 70 can run for up to 10 min.
with 150% of max. rated flow at LP inlet. The time
where max. rated flow is exceeded should be kept
as short as possible to minimize wear.
5)
Continuous operation: MPE 70 can operate
continuously with up to 10% over flush with the
limitation that the flow rate at LP inlet shall not
exceed 70 m
3
/h.
Summary of Contents for MPE 70
Page 25: ...Data sheet Energy Recovery Device MPE 70 hpp danfoss com...
Page 53: ...Parts list Energy recovery device MPE 70 hpp danfoss com...
Page 58: ...Danfoss DCS im 2022 08 AX367028596447en 000301 58...
Page 59: ...M a n u a l Electric Motors Motor Manual hoyermotors com...
Page 63: ...63 180R9426 AQ367027814446en 000801 IOM MPE 70 08 2022...