Notes
Reference should always be made to the I-100
Victaulic® Field Installation Handbook for the
product you are installing
www.victaulic.com
All References are based Victaulic “Duplex –
grooved couplings 17.20”.
1)
At least 2 flexible couplings must be used to compensate radial misalignment. Angular deflection of each
joint must not exceed Maximum angle from centerline. Se example reference “Victaulic – Design Data 26.01
page 3.
2)
The grooved piping method will not allow both maximum linear movement and maximum angular move
ment simultaneously at the same joint.
3)
End Loads are total, from all internal and external loads, based on duplex stainless steel pipe.
Pipe support
Flexible coupling Styles 77 and others standard
grooved-type couplings allow angular, linear and
rotational movement at each joint, to accommo-
date expansion, contraction, settling,
vibration, noise and other piping movement.
This must be considered when determinate
hanger and support bracing. See Reference
Victaulic – Design Data 26.01.
Victaulic®
Flexible coupling
Style 77DX
Cut grooved
Pipe SC40
3” pipe
X
Lmin
1
1000/36 x
1
= 28 mm
2
1000/36 x
2
= 56 mm
3
1000/36 x 3 = 84 mm
4
1000/36 x 4 = 111 mm
5
1000/36 x 5, = 139 mm
Minimum length at radial offset [mm]
Example
Lmin
© Danfoss | DHS (im) | 2020.10
180R9367 | AJ182686502974en-000301
| 52
Summary of Contents for MPE 70
Page 25: ...Data sheet Energy Recovery Device MPE 70 hpp danfoss com...
Page 53: ...Parts list Energy recovery device MPE 70 hpp danfoss com...
Page 58: ...Danfoss DCS im 2022 08 AX367028596447en 000301 58...
Page 59: ...M a n u a l Electric Motors Motor Manual hoyermotors com...
Page 63: ...63 180R9426 AQ367027814446en 000801 IOM MPE 70 08 2022...