6.3 Adjustment possibilities for the bracket
7.
Connecting the MPE 70
to the manifolds
7.1 Pipe connections
The MPE connection ports are designed for
hard piping. Danfoss recommends following
the Guideline 180R9367 - Pipe connection. This
guideline is based on the use of Victaulic® Style
77 Flexible Coupling.
Spool pieces must be manufactured according to
the “Victaulic® (OGS) cut groove specifications”
or similar.
To allow for inaccuracies in the manifolds and
to ensure an easy installation we recommend
mounting a spool piece with a minimum length
of 80 mm on the HP-out connection.
7.2 Manifolds
The manifolds must have enough support to
prevent them from moving when getting pres-
surized.
The manifolds must be clean inside before con-
necting them to the MPE 70.
The Danfoss bracket allows for ajustment in X-,
Y-, Z- direction during the alignment proces.
X
X
X
X
Y
Z
Max. 15 mm