H1P 115/130 suction filtration, option L
239.4 ± 1.0
[9.426 ± 0.039]
System port “B”
∅
31.5 – 450 bar
Split flange boss
per ISO 6162
M12 x 1.75
20 min.
full thread depth
System port “A”
∅
31.5 – 450 bar
Split flange boss
per ISO 6162
M12 x 1.75
20 min.
full thread depth
Charge inlet port “S”
Port ISO 11926-1 – 1
5
/
8
-12
∅
69 max. clearance dia for fitting
System B gage port “MB”
Port ISO 11926-1 –
9
/
16
-18
∅
28 max. Clearance Dia for Fitting
Charge pressure port
Port ISO 11926-1 –
5
/
16
-24
P003 403E
Please contact Danfoss representative for specific installation drawings.
Technical Information
H1 Axial Piston Single Pumps, Size 115/130
Filtration
62 |
©
Danfoss | May 2017
11063346 | BC00000198en-US0801