CCO solenoid data
Nominal supply voltage
12 V
24 V
Supply voltage
Maximum
14.6 V
29 V
Minimum
9.5 V
19 V
Nominal coil resistance at 20°C
10.7 Ω
41.7 Ω
Supply current
Maximum
850 mA
430 mA
Minimum
580 mA
300 mA
PWM frequency
Range
50-200 Hz
50-200 Hz
Preferred
100 Hz
100 Hz
Electrical protection class
IP67 / IP69K with mating connector
Bi-directional diode cut off voltage
28 V
53 V
Brake gauge port with MDC
C
Caution
It is not recommended to use brake port for any external flow consumption to avoid malfunction of CCO
function.
Displacement limiter
H1 pumps are designed with optional mechanical displacement (stroke) limiters factory set to max.
displacement. The maximum displacement of the pump can be set independently for forward and
reverse using the two adjustment screws to mechanically limit the travel of the servo piston down to 50
% displacement.
Adjustments under operating conditions may cause leakage. The adjustment screw can be completely
removed from the threaded bore if backed out to far.
P003 266
H1P 115/130 Displacement Change (Approximately)
Parameter
Size 115
Size 130
1 Turn of displacement limiter screw
10.8 cm
3
[0.66 in
3
]
12.2 cm
3
[0.74 in
3
]
Internal wrench size
6 mm
External wrench size
22 mm
Torque for external hex seal lock nut
80 N•m [708 lbf•in]
For more information, see
H1 Axial Piston Pumps, Service Manual,
AX00000087, the section “Displacement
Limiter Adjustment”.
Technical Information
H1 Axial Piston Single Pumps, Size 115/130
Control Options
©
Danfoss | May 2017
11063346 | BC00000198en-US0801 | 37