EDC Control Signal Requirements
Control minimum current to stroke pump
Voltage
a
*
b
Pin connections
12 V
640 mA
1640 mA
any order
24 V
330 mA
820 mA
*
Factory test current, for vehicle movement or application actuation expect higher or lower value.
1
2
P003 480
Connector ordering data
Description
Quantity
Ordering data
Mating connector
1
DEUTSCH DT06-2S
Wedge lock
1
DEUTSCH W2S
Socket contact (16 and 18 AWG)
2
DEUTSCH 0462-201-16141
Danfoss mating connector kit
1
K29657
EDC Solenoid Data
Description
12 V
24 V
Maximum current
1800 mA
920 mA
Nominal coil resistance
@ 20 °C [68 °F]
3.66 Ω
14.20 Ω
@ 80 °C [176 °F]
4.52 Ω
17.52 Ω
Inductance
33 mH
140 mH
PWM signal frequency
Range
70 – 200 Hz
Recommended
*
200 Hz
IP Rating
IEC 60 529
IP 67
DIN 40 050, part 9
IP 69K with mating connector
Connector color
Black
*
PWM signal required for optimum control performance.
Pump output flow direction vs. control signal
Shaft rotation
CW
CCW
Coil energized
*
C1
C2
C1
C2
Port A
out
in
in
out
Port B
in
out
out
in
Servo port pressurized
M4
M5
M4
M5
*
For coil location see Installation drawings.
Technical Information
H1 Axial Piston Single Pumps, Size 115/130
Control Options
18 |
©
Danfoss | May 2017
11063346 | BC00000198en-US0801