P005 933
X3
L2
M3
M5
E
F
MB
M14
1
1
2
1. Charge pressure construction port
5
∕
16
–24
2. Connector (Deutsch DT04-2P) to be paint free
Ports per ISO 11926-1 description
Port
Description
Size 115/130
E
,
F
Charge filtration port from/to filter
1
1
∕
16
–12 Ø42
max clearance dia for fitting
L2
Case drain port
1
5
∕
16
–12; Ø63
max clearance dia for fitting
X3
Case pressure port
1
1
∕
16
–12; Ø41
max clearance dia for fitting
MB
System B gauge port
9
∕
16
–18; Ø28
max clearance dia for fitting
M3
Charge gauge port, after filtering
9
∕
16
–18; Ø28
max clearance dia for fitting
M5 / M14
Servo / Case gauge port
7
∕
16
–20; Ø21
max clearance dia for fitting
Please contact Danfoss representative for specific installation drawings.
Technical Information
H1 Axial Piston Single Pumps, Size 115/130
Installation drawings
50 |
©
Danfoss | May 2017
11063346 | BC00000198en-US0801