H1 Pump General Specification
Design
Axial piston pump of cradle swashplate design with variable displacement
Direction of rotation
Clockwise, Counterclockwise
Pipe connections
Main pressure ports:
ISO split flange boss
Remaining ports:
SAE straight thread O-ring boss
Recommended installation
position
Pump installation position is discretionary, however the recommended control position is on the top or at the side
with the top position preferred.
If the pump is installed with the control at the bottom, flushing flow must be provided through port M14 located on
the EDC, FNR and NFPE control.
Vertical input shaft installation is acceptable.
If input shaft is at the top 1 bar case pressure must be maintained during operation.
The housing must always be filled with hydraulic fluid.
Recommended mounting for a multiple pump stack is to arrange the highest power flow towards the input source.
Consult Danfoss for nonconformance to these guidelines.
Auxiliary cavity pressure
Will be inlet pressure with internal charge pump. For reference see
H1P 115/130 Operating Parameters
.
Will be case pressure with external charge supply. Please verify mating pump shaft seal capability.
H1P 115/130 Technical Data
Feature
Size 115
Size 130
Displacement
115.2 cm
3
[7.03 in
3
]
130.0 cm
3
[7.93 in
3
]
Flow at rated (continuous) speed
371 l/min
[98 US gal/min]
419 l/min
[111 US gal/min]
Torque at maximum displacement
(theoretical)
1.83 N•m/bar
[1120 lbf•in/1000 psi]
2.07 N•m/bar
[1260 lbf•in/1000 psi]
Mass moment of inertia of rotating
components
0.021 kg•m
2
[0.0155 slug•ft
2
]
Mass (dry)
83 kg [187 lb]
(without charge pump or auxiliary mounting flange)
Oil volume
2.0 l [0.5 US gal]
Mounting flange
ISO 3019-1 Flange 152-4 (SAE D)
Input shaft outer diameter, splines and
tapered shafts
ISO 3019-1:
•
Outer Ø44 mm – 4 (SAE D, 13 teeth)
•
Outer Ø44 mm – 4 (SAE D, 27 teeth)
•
Conical keyed shaft end similar to ISO 3019-1 code 44-3, taper 1:8
Auxiliary mounting flange with metric
fasteners,
Shaft outer diameter and splines
ISO 3019-1:
•
Flange 82-2 Outer Ø16 mm – 4 (SAE A, 9 teeth)
•
Flange 82-2 Outer Ø19 mm – 4 (SAE A, 11 teeth)
•
Flange 101-2 Outer Ø22 mm – 4 (SAE B, 13 teeth)
•
Flange 101-2 Outer Ø25 mm – 4 (SAE B-B, 15 teeth)
•
Flange 127-4 Outer Ø32 mm – 4 (SAE C, 14 teeth)
•
Flange 152-4 Outer Ø44 mm – 4 (SAE D, 13 teeth)
Suction port
ISO 11926-1 – 1
5
∕
8
–12 (SAE O-ring boss)
Main port configuration
Ø31.5 - 450 bar split flange boss per ISO 6162, M12x1.75
Case drain ports L2, L4
ISO 11926-1 – 1
5
∕
16
–12 (SAE O-ring boss) (SAE O-ring boss)
Other ports
SAE O-ring boss
Customer interface threads
Metric fasteners
Technical Information
H1 Axial Piston Single Pumps, Size 115/130
Technical specifications
©
Danfoss | May 2017
11063346 | BC00000198en-US0801 | 5