Pa
r. No.
#
Pa
rame
ter de
script
ion
D
ef
au
lt
va
lue
4-
set-
up
Chang
e
duri
ng
op
er-
ati
on
Conve
r-
sion
inde
x
Type
26
-0* An
alog I/
O Mode
26-
00
Term
inal
X
42/
1 Mo
de
[1]
Vo
ltag
e
All
set-
up
s
TR
U
E
-
Ui
nt
8
26-
01
Term
inal
X
42/
3 Mo
de
[1] V
ol
tag
e
Al
l s
et
-u
ps
TRU
E
-
Ui
nt8
26-
02
Term
inal
X
42/
5 Mo
de
[1]
Vo
ltag
e
All
set-
up
s
TR
U
E
-
Ui
nt
8
26
-1* An
alog In
pu
t X42/
1
26-
10
Term
inal
X42
/1 Lo
w
Vo
ltag
e
0.0
7
V
All
set-
up
s
TR
U
E
-2
Int16
26-
11
Te
rm
ina
l X42/1 H
igh Volt
age
10
.0
0 V
Al
l s
et
-u
ps
TRU
E
-2
Int1
6
26-
14
Term
. X42
/1 Lo
w
R
ef
./
Fe
ed
b.
Val
ue
0.
000 N/
A
All
set-
up
s
TR
U
E
-3
Int32
26-
15
Te
rm.
X
42/
1 H
ig
h
Ref
./Fe
ed
b.
Va
lu
e
100.
000 N/
A
Al
l s
et
-u
ps
TRU
E
-3
Int3
2
26-
16
Term
. X42
/1 Fi
lte
r
Ti
me Constan
t
0.
001 s
All
set-
up
s
TR
U
E
-3
U
int16
26-
17
Te
rm
. X42
/1 Live
Ze
ro
[1
] E
nab
led
Al
l s
et
-u
ps
TRU
E
-
Ui
nt8
26
-2* An
alog In
pu
t X42/
3
26-
20
Te
rm
ina
l X42/3 Low Volt
age
0.0
7 V
Al
l s
et
-u
ps
TRU
E
-2
Int1
6
26-
21
Term
inal
X42
/3 H
ig
h Vo
ltag
e
10.0
0 V
All
set-
up
s
TR
U
E
-2
Int16
26-
24
Te
rm.
X
42/
3 Low
Ref
./
Fe
ed
b.
Va
lu
e
0.
000 N/
A
Al
l s
et
-u
ps
TRU
E
-3
Int3
2
26-
25
Term
. X42
/3 Hi
gh
R
ef
./
Fee
db
.
Va
lu
e
100.
000 N/
A
All
set-
up
s
TR
U
E
-3
Int32
26-
26
Te
rm
. X42/3 Filter
Time
Co
nstan
t
0.
001 s
Al
l s
et
-u
ps
TRU
E
-3
Ui
nt1
6
26-
27
Term
. X42
/3 Live
Zero
[1
] Enabl
ed
All
set-
up
s
TR
U
E
-
Ui
nt
8
26
-3* An
alog In
pu
t X42/
5
26-
30
Term
inal
X42
/5 Lo
w
Vo
ltag
e
0.0
7
V
All
set-
up
s
TR
U
E
-2
Int16
26-
31
Te
rm
ina
l X42/5 H
igh Volt
age
10
.0
0 V
Al
l s
et
-u
ps
TRU
E
-2
Int1
6
26-
34
Term
. X42
/5 Lo
w
R
ef
./
Fe
ed
b.
Val
ue
0.
000 N/
A
All
set-
up
s
TR
U
E
-3
Int32
26-
35
Te
rm.
X
42/
5 H
ig
h
Ref
./Fe
ed
b.
Va
lu
e
100.
000 N/
A
Al
l s
et
-u
ps
TRU
E
-3
Int3
2
26-
36
Term
. X42
/5 Fi
lte
r
Ti
me Constan
t
0.
001 s
All
set-
up
s
TR
U
E
-3
U
int16
26-
37
Te
rm
. X42
/5 Live
Ze
ro
[1
] E
nab
led
Al
l s
et
-u
ps
TRU
E
-
Ui
nt8
26
-4* An
alog Out
X42
/7
26-
40
Te
rm
ina
l X42/7 O
utpu
t
[0
] No
op
er
at
io
n
Al
l s
et
-u
ps
TRU
E
-
Ui
nt8
26-
41
Term
inal
X42
/7 Mi
n.
Scale
0.
00 %
All
set-
up
s
TR
U
E
-2
Int16
26-
42
Te
rm
in
al
X42
/7 M
ax.
S
cal
e
100.
00 %
Al
l s
et
-u
ps
TRU
E
-2
Int1
6
26-
43
Term
inal
X42
/7 Bus
Co
nt
ro
l
0.
00 %
All
set-
up
s
TR
U
E
-2
N
2
26-
44
Te
rm
ina
l X42/7 Timeo
ut Pre
se
t
0.
00 %
1 set-up
TRU
E
-2
Ui
nt1
6
26
-5* An
alog Out
X42
/9
26-
50
Te
rm
ina
l X42/9 O
utpu
t
[0
] No
op
er
at
io
n
Al
l s
et
-u
ps
TRU
E
-
Ui
nt8
26-
51
Term
inal
X42
/9 Mi
n.
Scale
0.
00 %
All
set-
up
s
TR
U
E
-2
Int16
26-
52
Te
rm
in
al
X42
/9 M
ax.
S
cal
e
100.
00 %
Al
l s
et
-u
ps
TRU
E
-2
Int1
6
26-
53
Term
inal
X42
/9 Bus
Co
nt
ro
l
0.
00 %
All
set-
up
s
TR
U
E
-2
N
2
26-
54
Te
rm
ina
l X42/9 Timeo
ut Pre
se
t
0.
00 %
1 set-up
TRU
E
-2
Ui
nt1
6
26
-6* An
alog Out
X42
/11
26-
60
Te
rm
ina
l X42/11
O
utput
[0
] No
op
er
at
io
n
Al
l s
et
-u
ps
TRU
E
-
Ui
nt8
26-
61
Term
inal
X42
/11
Mi
n. Scal
e
0.
00
%
All
set-
up
s
TR
U
E
-2
Int16
26-
62
Te
rm
ina
l X42/11 Max. Scale
100.
00 %
Al
l s
et
-u
ps
TRU
E
-2
Int1
6
26-
63
Term
inal
X42
/11
Bus Co
ntr
ol
0.
00
%
All
set-
up
s
TR
U
E
-2
N
2
26-
64
Te
rm
ina
l X42/11 Timeou
t Prese
t
0.
00 %
1 set-up
TRU
E
-2
Ui
nt1
6
8.3.2
2
Analog
I/O Option MCB
1
09 26-*
*
Automation VT Drive FC322
Instruction Manual
8 How to Programme the Frequency Converter
MG.20.U1.22
149
8