Danfoss ET4000 Crimp Machine Operator’s Manual
AQ439269047772en-000101
© Danfoss ET4000 Crimp Machine Operator’s Manual | 2023.02. | 9
6.
TURN locator bracket 90˚ until
aligned properly.
7.
SELECT the proper collet
assembly for hose type being
crimped as referenced in the
PowerSource Crimp Spec tool
at danfoss.com/crimp and
insert the collet assembly into
the base adapter ring.
NOTE:
Lubricate the inside
cone of the base adapter
ring and external surfaces of
the collet assembly with a
high-efficiency PTFE-based
lubricant.
8.
INSERT the hose assembly
through the bottom of
the base adapter ring and
between the two collet
assembly halves. Align the
fitting with the top of the
collet halves as referenced in
the PowerSource Crimp Spec
tool at danfoss.com/crimp.
9.
CLOSE the pusher halves and
begin crimping by activating
the pump with turning on
the switch. When the pusher
halves or spacer ring (if
applicable) contacts the base
adapter ring, the crimp is
complete.
10. RELEASE the switch and the
pusher will automatically
return. OPEN the pusher halves
and remove the crimped hose
assembly.
11. Visually inspect the crimp
and verify the correct crimp
diameter and length.
Refer to safety information regarding Danfoss hose,
hose fittings, and assembly compatibility on page 3.
Eye protection required when press and pump are in use.
NOTE: Based on the fitting style, correctly
align the fitting with the top of the collet
!