Danfoss ET4000 Crimp Machine Operator’s Manual
AQ439269047772en-000101
© Danfoss ET4000 Crimp Machine Operator’s Manual | 2023.02. | 7
Operating Instructions
Using ET4000AR-001
Refer to safety information regarding Danfoss hose,
hose fittings, and assembly compatibility on page 3.
Eye protection required when press and pump are in use.
NOTE: Based on the fitting style, correctly
align the fitting with the top of the collet
!
1.
OPEN the pusher halves. Select
the proper collet assembly for
hose type being crimped as
referenced in the PowerSource
Crimp Spec tool at danfoss.
com/crimp and insert the
collet assembly into the base
adapter ring.
NOTE: Lubricate the inside
cone of the base adapter
ring and external surfaces of
the collet assembly with a
high-efficiency PTFE based
lubricant.
2.
INSERT the hose assem-
bly through the bottom of
the base adapter ring and
between the two collet
assembly halves. Align the
fitting with the top of the
collet halves as referenced in
the PowerSource Crimp Spec
tool at danfoss.com/crimp.
3.
PLACE the spacer ring (if
applicable) in the appropriate
position on top of the collet
assembly (either flat-side up or
flat-side down as referenced in
the PowerSource Crimp Spec
tool at danfoss.com/crimp).
4.
CLOSE the pusher halves and
begin crimping by activating
the pump with turning on
the switch. When the pusher
halves or spacer ring (if
applicable) contacts the base
adapter ring, the crimp is
complete.
5.
RELEASE the switch and the
pusher will automatically
return. OPEN the pusher halves
and remove the crimped hose
assembly.
6.
Visually inspect the crimp
and verify the correct crimp
diameter and length.