2. Cut the cable sheath at the distance A from the end of the cable, see Figure below. Pull the cut
part of the sheath partly (length B is from 10 to 15 mm) off the cable as shown in the gure.
Distance A depends of the lenght of the used cable lug. Measure with the cable lug that is used
and cut to suitable lenght.
Do not remove the cable sheath completely at this point and do not cut the braid screen of the cable.
Figure 26. Cut lenght of the cable sheath
3. Insert the cable to the cable gland with slight turning motion. This helps the cable go through
the spring inside the cable gland. Push the cable gland against the sheath of the cable as shown in
Figure below.
Figure 27. Cable to the gland assembly
4. After the cable gland is in place remove the length A piece of the sheath and cut the braid
screen (cover) from 10 mm (distance C) from the gland bottom as shown in Figure below.
EC-C1200-450
5. Installation
44 |
©
Danfoss | Produced By: Danfoss Power Solutions | January 2019