Table 7. Example of the equipment needed for the assembly
Description
Manufacturer's homepage
Art.No./Part No.
Assembly equipment (example)
Torque key and turnkey head
730N710-50
Key
SE30
Assembly example for a 70 mm
2
cable
Cable with nominal cross-section of 70
mm
2
Radox Elastomer S
Cable lug
10857
Cable gland
P itsch blueglobe TRI bg
225ms tri
Screw
DIN 7984 M8 12 mm
Assembly example for a 50 mm
2
cable
Cable with nominal cross-section of 50
mm
2
Radox Elastomer S
C able lug
10853
Cable gland
P itsch blueglobe TRI bg
225ms tri
Screw
DIN 7984 M8 12 mm
Cabling and wiring
Route the power cables as far from the control signal wires as possible. The minimum separating distance is 100 mm. The
crossings must be in an angle of 90º. Power cables and control wires should be routed near the frame of the application.
Make sure that all terminal connections are tightened correctly.
If the electric device drives a motor or generator, contact Danfoss if the power cable is longer than 15 m. For EMC-reasons,
a lter might be needed.
Install the electric device by the instructions. Make sure that all the applications of the system, for
example, batteries are connected to the electric device by the instructions of this user guide and
the product speci c guidelines.
Cabling
For the power cables, it is recommended to use Radox Elastomer S, screened automotive cable
or equivalent cable with similar speci cations.
Cable cross section can be 35 mm
2
, 50 mm
2
, or max. 70 mm
2
, depending on the maximum
current of the electric device.
Use only EMI-shielded power cables to make sure the correct operation of the electric device
and to minimize the radiated emissions. Cable shields must be connected to the electric device
ground at both ends of the cable. All Danfoss mobile electri cation products use EMI-shielded
cable glands for power connections.
Wiring
To make sure of correct and steady operation, use EMI-shielded cables for the control signals of the
electric device. Cable shields must be connected to the electric device ground at both ends of the
cable.
EC-C1200-450
5. Installation
48 |
©
Danfoss | Produced By: Danfoss Power Solutions | January 2019
| BC265735231757en-000109