Recommended coolants
Ethylene glycol is a toxic compound. Avoid exposure to the coolant. Handle with care. Use appropriate personal
protective equipment when you handle the coolant.
The electric device works correctly with water based coolant. Plain water with appropriate
corrosive inhibitor is acceptable, for example water with maximum of 50% glycol coolant. Ethylene
glycol based Glysantin
®
G48
®
(includes also corrosion inhibitors) or similar can be used. Propylene
glycol based coolants, like Splash
®
RV&Marine antifreeze, can also be used. Propylene glycol is
relatively safe compound for humans and the environment.
Electrical installation
Before you start the electrical installation make sure that the frame of the electric device is grounded correctly. Refer to
Chapter
Risk of electric shock when power terminal cover is open. When working with the power connections make sure that
electricity has been disconnected and the electric device has discharged.
Cable lugs are not included in the delivery.
Refer to wiring diagram for details about electrical wiring.
References to EC-LTS are only for electrical devices with +DC -option.