Figure 30. Connecting cable lug
7. Cut piece of shrink tube and shrink it over the cable lug and braid screen as shown in Figure
below. This is done to keep the braid screen in place and for extra insulation.
The shrink tube must be speci ed for operating temperature range from -40 ºC to 150 ºC. Self gluing shrink tube is
recommended.
Figure 31. Shrink tube
8. Insert the cable through the corresponding hole in the electric device frame and connect the
cable lug to the power terminal with the correct screw. Use spring washer between the cable lug
and the connection screw or nut. Do not tighten the cable lug screw at this point to ensure tting
of the cable gland.
Make sure that there is at least 10 mm air gap in between the cable lug and other metallic structures including the braid
of the cable. If the air gap is smaller, use extra insulation shrink tube to cover the lug.
9. Screw the cable gland to the power terminals of the electric device according to instructions.
Tighten the cable gland with the speci ed torque.