Do not turn the body of the gland. Seal the cable to the cable gland by tightening from the cap of the gland. At the same
time, the cable gland is tightened to the terminal frame with correct torque.
10. Tighten the cable lug using the speci ed torque.
11. Repeat the procedure to the other cables and connections.
12. Close the power terminal cover and install the connector shield.
13. Make sure that the power cable shields are grounded properly.
Figure 32. Cable lug and cable gland assembly cross- section
EC-C1200-450
5. Installation
| BC265735231757en-000109
©
Danfoss | Produced By: Danfoss Power Solutions | January 2019 | 47