Class ID 0x29 Control Supervisor Object
Instance Attributes
Attribute Access
Name
Data Type
Description
1
Get
Number of Attributes
supported
USINT 12
2
Get
List of supported
Attributes
Array of
USINT
3,4,4,5,6,7,8,9,10,11,12,13,15
3
Get/Set Run 1 (forward)
Boolean FC CTW Bit 6 = Run1 XOR Run2
FC CTW Bit15 = 0
4
Get/Set Run 2 (reverse)
Boolean FC CTW Bit 6 = Run1 XOR Run2
FC CTW Bit15 = 1
5
Get/Set Network Control
Boolean Parameter 12-32 value written from option
6
Get
State
USINT
The state of the CIP state-machine
7
Get
Running 1
Boolean Run1 AND bit 11 in FC STW
8
Get
Running 2
Boolean Run2 AND bit 11 in FC STW
9
Get
Ready
Boolean STATE_ENABLED or STATE_STOPPING or
STATE_FAULT_STOP from state-machine
10
Get
Faulted
Boolean Bit 3 in FC STW
11
Get
Warning
Boolean Bit 7 in FC STW
12
Get/Set Fault reset
Boolean Bit 7 in FC CTW
13
Get
Fault Code
UINT
Mapping of par. 16-90 Alarm Word to CIP
specific fault codes
15
Get
Control from net
Boolean Parameter 12-31 value written from option
Attribute 13 “Fault Code”
CIP Malfunction
Code
Meaning
VLT-Code
Alarmword
CIP Malfunction
Meaning
CIP
Classification
0
No alarm
0000 0000
No fault
-
0
unused
0000 0001
No fault
-
4210
Drive over temperature
0000 0002
Excessive Device
Temperature
mar
2240
Earth fault
0000 0004
Short to earth
mau
0
unused
0000 0008
No fault
-
8100
Controlword timeout
0000 0010
Communication
mir
2310
Overcurrent
0000 0020
Continuous Overcurrent mau
8302
Torque limit
0000 0040
Torque limiting
mar
4310
Motor thermistor
0000 0080
Excess Drive
Temperature
mar
4310
Motor ETR over temp
0000 0100
Excess Drive
Temperature
mar
2311
Inverter overloaded
0000 0200
Current inside the
device, No. 1
mar
3220
DC Link undervoltage
0000 0400
Undervoltage inside the
Device
mar
3210
DC Link overvoltage
0000 0800
Overvoltage inside the
device
mar
2130
Short circuiting
0000 1000
Short Circuit
mau
2213
Inrush fault
0000 2000
Overcurr. during startup mar
3130
Mains phase loss
0000 4000
Phase Failure
mau
5210
AMT fail
0000 8000
Measurement Circuit
mir
1000
Live zero fault
0001 0000
General fault
mar
6100
Internal fault
0002 0000
Internal software fault mau
7110
Brake resistor power limit
0004 0000
Brake Chopper
mau
3300
Motor phase U missing
0008 0000
Output voltage
mau
3300
Motor phase V missing
0010 0000
Output voltage
mau
3300
Motor phase W missing
0020 0000
Output voltage
mau
8100
Fieldbus Comm. fault
0040 0000
Communication
mir
5112
24V supply fault
0080 0000
+24V Power supply
mau
3100
Mains failure
0100 0000
Mains Voltage
mar
5110
1,8V supply fault
0200 0000
Low voltage power
supp.
mau
7110
Brake resist. short circ.
0400 0000
Brake chopper
mar
7110
Brake chopper fault
0800 0000
Brake chopper
mar