32
•
Camera Operation
parameters and modify on-board buffer allocation if the buffer size has changed since the
last acquisition.
Timing
tLine Period
twSYNC_INT
twSYNC
tPR_INT
twPR_HIGH
twPR_LOW
tPR
EXSYNC
PRIN
Internal Line Valid
tTRANSFER
tREADOUT
tOVERHEAD
Ethernet Latency to PC
Memory
Valid Data From
Diagramed
ExSync
tEthernet Latency
Table 8: Timing Parameter Table
Units
Min.
Typ.
Max.
Notes
tLine_Period
μs
27.78
1000
1K 1 Tap
14.71
1000
1K 2 Tap
54.1
1000
2K 1 Tap
27.78
1000
2K 2 Tap
54.1
1000
4k 2 Tap
twSync
ns
100
twSYNC_INT
ns
100
(3000*)
For exposure mode 4 this value
needs to be >3000ns other wise
>100ns
tPR
ns
0
twPR_LOW
ns
3000
twPR_HIGH
ns
3000
tPR_INT
ns
3000
Table 9: tReadout Values
tREADOUT
Sensor Size
# Taps
Readout Time
1024
1
25600ns
1024
2
12800ns
2048
1
51200ns
2048
2
25600ns
4096
2