18
•
The Spyder3 SG-34 Cameras
5.
Select “Use the following IP address” and set the IP address to any address in this
subnet other than 192.168.5.100, which is used by the camera. In the example
below, the address 192.168.5.50 is used. Alternatively, select “Obtain an IP address
automatically” to use a dynamic address.
6.
Set subnet to: 255.255.255.0 and click on “OK.”
Figure 7. IP Address
7.
Click “OK” to save settings
8.
Click on “Configure” button and select “Advanced” tab
9.
Enable “Jumbo Frames” to greater than 9000 bytes. If your NIC does not support
jumbo packets the image transfer speed will be slower.