26
•
The Spyder3 SG-34 Cameras
The CamExpert application uses 5 windows to simplify choosing and configuring camera files
or acquisition parameters for the installed device.
•
Device Selector pane:
View and select from any installed Sapera acquisition device.
Once a device is selected CamExpert will only present acquisition parameters applicable
to that device. Optionally select a camera file included with the Sapera installation or
saved by the user.
•
Parameters pane:
Allows viewing or changing all acquisition parameters supported by
the acquisition device. CamExpert displays parameters only if those parameters are
supported by the installed device. This avoids confusion by eliminating parameter
choices when they do not apply to the hardware in use.
•
Display pane:
Provides a live or single frame acquisition display. Frame buffer
parameters are shown in an information bar above the image window.
•
Control Buttons:
The Display pane includes CamExpert control buttons. These are:
Acquisition control button:
Click once to start live grab, click again to stop.
Single frame grab:
Click to acquire one frame from device.
Software trigger button:
With the I/O control parameters set to Trigger Enabled / Software Trigger
type, click to send a single software trigger command.
CamExpert display controls:
(these do not modify the frame buffer data)
Stretch image to fit, set image display to original size, or zoom the image to
any size and ratio.
Histogram / Profile tool:
Select to view a histogram or line/column profile during live acquisition.
•
Output Message pane:
Displays messages from CamExpert or the device driver.