Mnemonic
Syntax
Parameters
Description
set sync frequ ency
ssf
i
Set the fram e rate to a valu e from
300
H z to
36000
H z
(2k m od el) or
300
H z to
68000
H z (1k m od el). Valu e
rou nd ed u p / d ow n as requ ired .
set system gain
ssg
t i
Set the d igital gain.
t
= tap selection, either
1
to
2
, or
0
for all tap s
i
= Digital gain in a range from
0
to
65535
. The d igital
vid eo valu es are m u ltip lied by this nu m ber.
set sensitivity m od e
ssm
i
Sets the camera’s sensitivity mod e w here i is:
0
= Low sensitivity m od e
1
= H igh sensitivity m od e
2
= Tall p ixel m od e
set u p p er threshold
sut
i
The p ixels equ al to or greater than the u p p er threshold
are checked for and rep orted in the end -of-line sequ ence
in a range from
0
-
4095
.
set vid eo m od e
svm
i
Sw itch betw een norm al vid eo m od e and cam era test
p atterns:
0
: N orm al vid eo m od e
1
: Cam era test p attern
2
: Cam era test p attern
u p d ate gain reference
ugr
Changes 0d B gain to equ al the cu rrent analog gain valu e
set w ith the
sag
com m and .
verify tem p eratu re
vt
Check the internal tem p eratu re of the cam era
verify voltage
vv
Check the camera’s input voltages and return OK or fail
w rite FPN coefficients
wfc
i
Write all cu rrent FPN coefficients to non-volatile
m em ory, w here
i
is:
1
= FPN coefficient set one
2
= FPN coefficient set tw o
3
= FPN coefficient set three
4
= FPN coefficient set fou r
w rite inp u t LUT
wil
i
Write current LUT’s to non -volatile memory.
i
=1 to 4
w rite PRN U coeffs
wpc
i
Write all cu rrent PRN U coefficients to non-volatile
m em ory, w here
i
is:
1
= PRN U coefficient set one
2
= PRN U coefficient set tw o
3
= PRN U coefficient set three
4
= PRN U coefficient set fou r
w rite u ser settings
wus
Write all of the u ser settings to non-volatile m em ory.
Error Handling
The follow ing table lists w arning and error m essages and p rovid es a d escrip tion and p ossible cau se.
Warning m essages are retu rned w hen the cam era cannot m eet the fu ll valu e of the requ est; error
m essages are retu rned w hen the cam era is u nable to com p let e the requ est.
Table 16: Warning and Error Messages
Message
Description
OK>
SUCCESS