4. Save the PRN U coefficients u sing the com m and
w pc.
For exam p le: w p c
N ote: Both the FPN and PRN U coefficients are alw ays tu rned on.
Digital Signal Processing
To op tim ize cam era p erform ance, d igital signal p rocessing shou ld be com p leted after any analog
ad ju stm ents.
FPN Correction
Perform s FPN correction and elim inates FPN noise by rem oving ind ivid u al p ixel d ark cu rrent.
Camera Link Command
Parameter
Description
Notes
ccf
Perform all analog and d igital ad ju stm ents
before p erform ing FPN correction.
Perform FPN correction before PRN U
correction.
Refer to Calibrating the Cam era to Rem ove
N on-Uniform ity (Flat Field Correction) on
p age 51 for a p roced u ral overview on
p erform ing flat field correction.
To save FPN coefficients after calibration,
u se the
w fc
com m and . Refer to section
Saving and Restoring PRN U and FPN
Coefficients for d etails.
Example
ccf