Spyder3 S3-14 and S3-24 Monochrome Camera User's Manual
41
Teledyne DALSA
03-032-20117-01
Mode 4: Smart EXSYNC, External Line Rate and Exposure Time
In this m od e, EXSYN C sets both the line p eriod and the exp osu re tim e. The rising ed ge of EXSYN C m arks
the beginning of the exp osu re and the falling ed ge initiates read ou t.
Example 3: Trigger Period is Repetitive and Greater than Read Out Time.
Mode 5: External Line Rate (EXSYNC) and External Pixel Reset
(PRIN)
In this m od e, the falling ed ge of EXSYN C sets the line p eriod and the rising ed ge of PRIN sets the start of
exp osu re tim e.
Figure 22: EXSYNC controls Line Period and PRIN controls Exposure Time
Mode 6: External Line Rate and Internally Programmable
Exposure Time
Figure 23: EXSYNC controls Line Period with Internally controlled Exposure Time
Readout
EXSYNC
Line Period
CR=Charge Reset
Readout
Line Period
Programmable Period
Using Command
set
Programmable Period
Using command
set
Readout
EXSYNC
Line Period
cr=Charge Reset
Readout
PRIN
Line Period
Line Period
Readout
EXSYNC
EXSYNC Falling
Edge ignored
during readout
Line Period
CR=Charge Reset
Readout
Line Period
EXSYNC Falling
Edge ignored
during readout