Spyder3 S3-14 and S3-24 Monochrome Camera User's Manual
33
Teledyne DALSA
03-032-20117-01
Factory Settings
On first initialization, the cam era op erates u sing the factory settings. You can restore the original factory
settings at any tim e u sing the com m and
rfs
.
User Settings
You can save or restore you r u ser settings to non -volatile m em ory u sing the follow ing com m and s. Pixel
coefficients and LUTs are stored sep arately from other d ata.
To save all cu rrent u ser settings to non -volatile m em ory, u se the com m and w u s. The cam era w ill
au tom atically restore the saved u ser settings w hen p ow ered u p . N ote: While settings are being
w ritten to nonvolatile m em ory, d o not p ow er d ow n cam era or cam era m em ory m ay be
corru p ted .
To restore the last saved u ser settings, u se the com m and ru s.
To save the cu rrent p ixel coefficients, u se the com m and w p c and w fc.
To restore the last saved p ixel coefficients, u se the com m and lp c.
To w rite LUTs, u se the w il com m and .
Current Session Settings
These are the cu rrent op erating settings of y ou r cam era. To save these settings to non -volatile m em ory,
u se the com m and
wus
.
Camera Output Format
How to Configure Camera Output
Using the camera link mode and pixel readout direction commands
Use the cam era link m od e (
clm
)
com m and to d eterm ine the cam era’s Cam era Link configu ration, the
nu m ber of ou tp u t tap s, and the bit d ep th. Use the p ixel read ou t d irection (
smm)
com m and to select the
camera’s pixel read out d irection.
The follow ing tables su m m arize the p ossible cam era con figu rations for each of the S3-xx cam era m od els.
Table 11: Data Readout Configurations
Mode Configuration
Readout Direction
Command
Models
Taps Bit Depth
smm 0 increment =1
smm 1 increment = -1
clm 0
S3-14-01K40
1
8
smm
0
= CL tap 1 (1-1024)
smm 1
= CL tap 1 (1024-1)
S3-14-02K40
smm
0
= CL tap 1 (1-2048)
smm 1
= CL tap 1 (2048-1)
clm 1
S3-14-01K40
1
12
smm
0
= CL tap 1 (1-1024)
smm 1
= CL tap 1 (1024-1)
S3-14-02K40
smm
0
= CL tap 1 (1-2048)
smm 1
= CL tap 1 (2048-1)
clm 2
S3-24-01K40
2
8
smm
0
= CL tap 1 (1-512)
CL tap 2 (513-1024)
smm 1
= CL tap 1 (1024-513)
CL tap 2 (512-1)
S3-24-02K40
2
smm
0
= CL tap 1 (1-1024)