Piranha 3 User Manual
03-032-10216-02
DALSA
28
Mode SYNC
PRIN
Description
8
Internal
Internal
No
Yes
Maximum line rate for exposure time.
ECE.
Note: When setting the camera to external signal modes, EXSYNC and/or PRIN must be supplied.
Exposure Modes in Detail
Mode 2: Internally Programmable Line Rate and Exposure Time
Mode 2 operates at a user specified line rate and exposure time.
•
When setting the line rate (using the
ssf
command), exposure time will be reduced,
if necessary, to accommodate the new line rate. The exposure time will always be set
to the maximum time (line period – line transfer time – pixel reset time) for that line
rate when a new line rate requiring reduced exposure time is entered.
•
When setting the exposure time (using the
set
command), line time will be
increased, if necessary, to accommodate the exposure time. Under this condition, the
line time will equal the exposure time + line transfer time.
Example 1: Exposure Time less than Line Period
Mode 3: External Trigger with Maximum Exposure
Line rate is set by the period of the external trigger pulses. The falling edge of the external
trigger marks the beginning of the exposure.
Example 2: Line Rate is set by External Trigger Pulses.
Programmable Period (
set
command)
Line Period
Readout
CR
Exposure Time
CR=Charge Reset
Line Period
Programmable Period
CR
Exposure Time
Programmable Period (
ssf
command)
Readout
Programmable Period
Line Period
Exposure Time
Line Period
Readout
Exposure Time
Falling Edge
Ignored During
Readout
Readout
Falling Edge
Ignored During
Readout
EXSYNC
Summary of Contents for Piranha3
Page 6: ...Piranha 3 User Manual 03 032 10216 02 DALSA 6...
Page 14: ...Piranha 3 User Manual 03 032 10216 02 DALSA 14...
Page 22: ...Piranha 3 User Manual 03 032 10216 02 DALSA 22...
Page 74: ...Piranha 3 User Manual 03 032 10216 02 DALSA 74...
Page 86: ...Piranha 3 User Manual 03 032 10216 02 DALSA 86 This Declaration corresponds to EN 45 014...
Page 88: ...Piranha 3 User Manual 03 032 10216 02 DALSA 88...