Piranha 3 User Manual
DALSA 03-032-10216-02
19
Input Signals, Camera Link
The camera accepts control inputs through the Camera Link MDR26F connector.
The camera ships in internal sync, internal programmed integration (exposure mode 2).
EXSYNC (Triggers Line Readout)
Line rate can be set internally using the serial interface. The external control signal
EXSYNC is optional and enabled through the serial interface. This camera uses the
falling
edge of EXSYNC
to trigger line readout. Section 3.2.1 Exposure Mode, Line Rate and
Exposure Time details how to set frame times, exposure times, and camera modes.
Output Signals, Camera Link
These signals indicate when data is valid, allowing you to clock the data from the camera
to your acquisition system. These signals are part of the Camera Link configuration and
you should refer to the DALSA Camera Link Implementation Road Map, available at
http://vfm.dalsa.com/
, for the standard location of these signals.
Clocking Signal
Indicates
LVAL (high)
Outputting valid line
DVAL (high)
Valid data
STROBE (rising edge)
Valid data
FVAL (high)
Outputting valid frame
• The camera internally digitizes 12 bits and outputs 8 MSB or all 12 bits depending on
the camera’s Camera Link operating mode. Refer to section 3.3.1 Setting the Camera
Link Mode for details on setting the Camera Link configuration.
• For a Camera Link reference refer to Appendix A on page 71.
2.3 Camera Link Video Timing
Figure 6: Piranha3 Overview Timing Showing Input and Output Relationships
IMPORTANT:
This camera’s data
should be sampled on
the rising edge of
STROBE.
i
Summary of Contents for Piranha3
Page 6: ...Piranha 3 User Manual 03 032 10216 02 DALSA 6...
Page 14: ...Piranha 3 User Manual 03 032 10216 02 DALSA 14...
Page 22: ...Piranha 3 User Manual 03 032 10216 02 DALSA 22...
Page 74: ...Piranha 3 User Manual 03 032 10216 02 DALSA 74...
Page 86: ...Piranha 3 User Manual 03 032 10216 02 DALSA 86 This Declaration corresponds to EN 45 014...
Page 88: ...Piranha 3 User Manual 03 032 10216 02 DALSA 88...