Piranha 3 User Manual
03-032-10216-02
DALSA
18
The Camera Link interface is implemented as a Medium or Full Configuration in the
Piranha3 cameras. Refer to section 3.3.1 Setting the Camera Link Mode for details on
setting the Camera Link configuration.
Table 7: Camera Link Hardware Configuration Summary
Configuration 8 Bit Ports
Supported
Serializer
Bit Width
Number
of Chips
Number of MDR26
Connectors
Medium
A, B, C, D, E, F
28
2
2
Full
A, B, C, D, E, F, G, H
28
3
2
Table 8: Camera Link Connector Pinout
Medium and Full Configuration
Camera Connector Right Angle
Frame Grabber
Channel Link
Signal
Cable Name
1
1
inner shield
Inner Shield
14 14 inner
shield
Inner
Shield
2
25
Y0-
PAIR1-
15 12 Y0+
PAIR1+
3
24
Y1-
PAIR2-
16 11 Y1+
PAIR2+
4
23
Y2-
PAIR3-
17 10 Y2+
PAIR3+
5
22
Yclk-
PAIR4-
18 9 Yclk+
PAIR4+
6
21
Y3-
PAIR5-
19 8 Y3+
PAIR5+
7
20
100 ohm
PAIR6+
20 7 terminated
PAIR6-
8
19
Z0-
PAIR7-
21 6 Z0+
PAIR7+
9
18
Z1-
PAIR8-
22 5 Z1+
PAIR8+
10
17
Z2-
PAIR9+
23 4 Z2+
PAIR9-
11
16
Zclk-
PAIR10-
24 3 Zclk+
12
15
Z3-
25 2 Z3+
PAIR11-
13
13
inner shield
Inner Shield
26 26 inner
shield
Inner
Shield
Table 9: DALSA Camera Control Configuration
Signal
Configuration
CC1 EXSYNC
CC2
PRIN
CC3 Spare
CC4
Spare
Summary of Contents for Piranha3
Page 6: ...Piranha 3 User Manual 03 032 10216 02 DALSA 6...
Page 14: ...Piranha 3 User Manual 03 032 10216 02 DALSA 14...
Page 22: ...Piranha 3 User Manual 03 032 10216 02 DALSA 22...
Page 74: ...Piranha 3 User Manual 03 032 10216 02 DALSA 74...
Page 86: ...Piranha 3 User Manual 03 032 10216 02 DALSA 86 This Declaration corresponds to EN 45 014...
Page 88: ...Piranha 3 User Manual 03 032 10216 02 DALSA 88...