![Dalsa Piranha ES Series User Manual Download Page 33](http://html.mh-extra.com/html/dalsa/piranha-es-series/piranha-es-series_user-manual_504454033.webp)
Piranha ES-xx User Manual
Teledyne DALSA
03-032-20070-02
33
spc set prnu coeff xi NA
ssb set subtract background ti 0-4:0-4095
ssf set sync frequency f 1-6169.03 [Hz]
ssg set system gain ti 0-4:0-65535
stg set stage m 16, 32
spt set pretrigger
i 0-16
sut set upper threshold i 0-4095
svm set video mode i 0-3
tdi set TDI or area mode i 0-1
ugr update gain reference
vt verify temperature
vv verify voltage
wfc write FPN coefficients NA
wpc write PRNU coefficients NA
wus write user settings
3.1 First Power Up Camera Settings
When the cam era is p ow ered u p for the first tim e, it op erates u sing the follow ing factory
settings:
TDI m od e
Left to right p ixel read ou t
Forw ard CCD shift d irection
Maxim u m integration stages
N o binning
Cam era Link Mod e: 21 (8 bit, 8 tap s, 40MH z strobe rate)
Exp osu re m od e 7 (internal sync, m axim u m exp osu re tim e)
10 kH z line rate
320 throu ghp u t
Factory calibrated analog gain and offset
Factory calibrated FPN and PRN U coefficients u sing the follow ing p rocess:
1.
ssf 10000
(line rate of 10000H z)
2.
ccg 2 0 3280
(analog gain calibrated to an average p ixel valu e of 3280)
3.
ccf
(fp n calibration)
4.
ccp
(p rnu calibration)
5.
ssg 0 0
Summary of Contents for Piranha ES Series
Page 22: ...Piranha ES xx User Manual 03 032 20070 02 Teledyne DALSA 22 ...
Page 88: ...Piranha ES xx User Manual 03 032 20070 02 Teledyne DALSA 88 ...
Page 102: ...Piranha ES xx User Manual 03 032 20070 02 Teledyne DALSA 102 ...
Page 104: ...Piranha ES xx User Manual 03 032 20070 02 Teledyne DALSA 104 ...