Symbol
Time
Frame Overhead
4
HCCD Frequency
VTransTime
33
HCCD Frequency
HCCD Read Overhead
ES 4k: and 8k: 34 clocks
HTime
HTime=
HCCD Read Ov HCCD Pixels/Tap
HCCD Frequency
CCD Readout Time
CCDReadoutTime = FrameOv HTime + VTransTime x Vertical Binning Factor
HCCD Taps
16 (ES-80-08k40, ES-80-08K80, ES-82-04k40, ES-82-04k80) or 8 (ES-80-04k40)
Line store Start Overhead
15 clocks
Line store End Overhead
23 clocks
Line store Readout Time
HCCD Pixels/Tap x HCCD Taps
# Camera Link Taps x Horizontal Binning Factor
+ Linestore Start O Linestore End Overhead
# Camera Link Taps
Throughput (MHz)
x
Horizontal Binning Factor
Value set with
sbh
command
Vertical Binning Factor
Value set with
sbv
command
Vertical Readout Rows
Stage selection set with
stg
command
# of Camera Link Taps
Value set with the
clm
command
Throughput
Value set with
sot
command
Figure 8: Piranha ES-xs Area Mode Timing (CCD Limited)
Figure 9: Piranha ES-xx Area Mode Timing (Line store Limited)
Table 9: Piranha Input and Output
Symbol
Time
CCD Readout Time
(Area Mode)
CCD ReadoutTime=Frame Ov HTime
Vertical readout rows + ISORows
Vertical Binning Factor
+
x
VTransTime
HCCD Frequency
Remainder
+
HTime
Vertical readout rows + ISORows
Vertical Binning Factor
+
x
VTrans
Integer
x Vertical Binning Factor
EXSYNC
User LVAL
User FVAL
Internal HTime
EXSYNC
User LVAL
User FVAL
IMPORTANT:
This camera uses the
falling
edge of EXSYNC
to trigger line readout,
unlike previous DALSA
cameras, which used the
rising edge.
Internal HTime
Summary of Contents for Piranha ES Series
Page 22: ...Piranha ES xx User Manual 03 032 20070 02 Teledyne DALSA 22 ...
Page 88: ...Piranha ES xx User Manual 03 032 20070 02 Teledyne DALSA 88 ...
Page 102: ...Piranha ES xx User Manual 03 032 20070 02 Teledyne DALSA 102 ...
Page 104: ...Piranha ES xx User Manual 03 032 20070 02 Teledyne DALSA 104 ...