Piranha 3 User Manual
03-032-10216-02
DALSA
76
Message
Description
Error 02:
Unrecognized
command>
Command is not available in the current access level or it is not a
valid command.
Error 03: Incorrect
number of
parameters>
Error 04: Incorrect
parameter value>
This response returned for
· Alpha received for numeric or vice versa
· Not an element of the set of possible values. E.g., Baud Rate
· Outside the range limit
Error 05: Command
unavailable in this
mode>
Command is valid at this level of access, but not effective. Eg line
rate when in smart Exsync mode
Error 06: Timeout>
Command not completed in time. Eg FPN/PRNU calculation when
no external exsync is present.
Error 07: Camera
settings not saved>
Tried saving camera settings (
rfs
/
rus)
but they cannot be saved.
Error 08: Unable to
calibrate - tap
outside ROI>
Cannot calibrate a tap that is not part of the end of line statistics.
Error 09: The
camera's
temperature exceeds
the specified
operating range>
Indicates that the camera has shut itself down to prevent damage
from further overheating.
B2 All Available Commands
As a quick reference, the following table lists all of the commands available to the camera
user. For detailed information on using these commands, refer to Chapter 3.
Command
Syntax Parameters Description
calibrate analog offset
cao
t i
Calibrates the analog gain and averages
each tap’s pixels within the ROI to the
specified average target value.
t
= tap selection, either
1
to
number of
CCD taps
, or
0
for all taps
i
= target value in a range from
0
to
255
DN (12-bit LSB)
Refer to Analog Signal Processing:
Setting Analog Gain and Offset for
details.
correction calibrate fpn
ccf
Start FPN coefficient calibration. Refer to
section 3.4.2 Analog and Digital Signal
Processing Chain for details.
Parameters:
i
= integer
t
= tap id
i
= integer value
f
= real number
s
= string
x1
= horizontal pixel start
number
x2
= horizontal pixel end
number
y1
= vertical pixel start
number
y2
= vertical pixel end
number
Summary of Contents for P3-80-**k40-R
Page 6: ...Piranha 3 User Manual 03 032 10216 02 DALSA 6 ...
Page 14: ...Piranha 3 User Manual 03 032 10216 02 DALSA 14 ...
Page 22: ...Piranha 3 User Manual 03 032 10216 02 DALSA 22 ...
Page 74: ...Piranha 3 User Manual 03 032 10216 02 DALSA 74 ...
Page 86: ...Piranha 3 User Manual 03 032 10216 02 DALSA 86 This Declaration corresponds to EN 45 014 ...
Page 88: ...Piranha 3 User Manual 03 032 10216 02 DALSA 88 ...