Piranha 3 User Manual
DALSA 03-032-10216-02
57
3.6.6 Returning Camera Settings
Returning All Camera Settings with the Camera Parameter
Screen
The camera parameter (gcp) screen returns all of the camera’s current settings. The table
below lists all of the gcp screen settings.
To read all current camera settings, use the command:
Syntax:
gcp
GCP Screen
Desctiption
GENERAL CAMERA SETTINGS
Camera Model No.:
P3-xx-xxxxx
Camera model number.
Camera Serial No.:
xxxxxxxxx
Camera serial number.
Firmware Design Rev.:
xx-xx-xxxxx-xx
Firmware design revision
number.
CGI Version:
03-81-xxxxx-xx
CGI version. Part of FPGA
firmware.
FPGA Design Rev.:
xxx.xx
DSP design revision
number.
UART Baud Rate:
9600
Serial communication
connection speed set with
the
sbr
command. See
Setting Baud Rate on page
24 for details.
Exposure Mode:
2
Current exposure mode
value set with the
sem
command. See section
3.2.1 Exposure Mode, Line
Rate and Exposure Time
for details.
SYNC Frequency:
5000 Hz
Current line rate. Value is
set with the
ssf
command. See section
3.2.1 Exposure Mode, Line
Rate and Exposure Time
for details.
Internal Exposure Time: 50 uSec
Current exposure time
setting. Value is set with
the
set
command. See
section 3.2.1 Exposure
Mode, Line Rate and
Exposure Time for details.
Video Mode:
video
Current video mode value
set with the
svm
command. See section
3.6.1 Generating a Test
Pattern for details.
Summary of Contents for P3-80-**k40-R
Page 6: ...Piranha 3 User Manual 03 032 10216 02 DALSA 6 ...
Page 14: ...Piranha 3 User Manual 03 032 10216 02 DALSA 14 ...
Page 22: ...Piranha 3 User Manual 03 032 10216 02 DALSA 22 ...
Page 74: ...Piranha 3 User Manual 03 032 10216 02 DALSA 74 ...
Page 86: ...Piranha 3 User Manual 03 032 10216 02 DALSA 86 This Declaration corresponds to EN 45 014 ...
Page 88: ...Piranha 3 User Manual 03 032 10216 02 DALSA 88 ...