I/O Controls Category
The Calibir GigE I/O controls, as shown by CamExpert, groups features used to configure an
external trigger input and acquisition actions based on the trigger. For more information on
connecting an external trigger input, see the 10-pin I/O Connector Details section.
Figure 33: CamExpert I/O Controls Category
I/O Controls Feature Descriptions
Table 12 describes these features along with their view attribute. Additionally the View column will
indicate which feature is a member of the DALSA Features Naming Convention (indicated by
DFNC), versus the GenICam Standard Features Naming Convention (SFNC tag is not shown).
Table 13: I/O Controls Feature Descriptions
Display Name
Feature & Values
Description
View
Trigger Selector
TriggerSelector
Selects which type of trigger to configure with the
various Trigger features.
Beginner
Frame Acquisition Trigger
AcquisitionStart Enables the selection of a trigger source that starts
the Acquisition of one or many frames.
Trigger Mode
TriggerMode
Controls the enable state of the selected trigger.
Beginner
Off
Off The selected trigger is turned off.
External trigger
On The selected trigger is turned active.
Trigger Frames Count
triggerFrameCount
Sets the total number of frames to acquire when a
valid trigger is received. This feature is available
when Trigger Selector = MultiFrame Trigger(Start).
DFNC
Beginner
Software Trigger
TriggerSoftware
Generate a software command internal trigger
immediately no matter what the TriggerSource
feature is set to.
Beginner
Trigger Source
TriggerSource
Specifies the internal signal or physical input line to
use as the trigger source. The selected trigger must
have its TriggerMode set to ON.
See Input Signal Electrical Specifications.
Beginner
Line 0
Line0 Select Line 0 (and associated I/O control block) to
use as the external trigger source. See LineSelector
feature for complete list.