[14]
MAN #650793
Technical specifications
Minimum operating voltage
9 volts
Maximum operating voltage
16 volts (operating over 15 volts for an extended time, can damage unit)
Typical current draw (@ 13.8V)
< 0.10 A for BIM-22-3 and associated TPMS Receiver Module.
Maximum pressure reading
99 psi
Gauge Resolution
1 psi
Low / High Warning Level range
5
– 99 psi
Default Low Warning
25 psi
Default High Warning
35 psi
Number of BIM ID numbers used
4 (one for each sensor)
Default BIM ID numbers
3 - 6
Control Box Compatibility
- The following versions of software (or newer) are required to function with the BIM-22-3
(Note: All RTX systems support this option):
Control Box / Dash
Minimum Software Version Required
VFD3 Control Box
SE4B
VFD3X Control Box
SE5A
VHX Control Box
VX0A (10)
VHX Gauge Cluster
####.010
(Example: VJ90.010)
HDX Control Box
HX02 or RX01
HDX Gauge Cluster
Any
RTX Control Box
RX01
RTX Gauge Cluster
Any
Summary of Contents for BIM-22-3
Page 15: ...15 MAN 650793 NOTES...