www.daisalux.com
30
LPS24
– USER MANUAL
8.2.4.2.
Luminaires (ELC)
On the luminaires screen, a summary will appear at the top of the luminaires registered
and with a fault on the device.
At the bottom, view the status and configure each of the luminaires registered. The
display is made by circuit; i.e., first select a circuit and then go to all luminaires
connected to this circuit.
Overview
OK
Main menu
>
Outputs
OK
Luminaires
LUMINAIRES
Installed:
75
In failure:
3
> Filter:
installed
>Circuit:
1
>Serial Number:
280542
Status:
ok-light on
* Mode:
Maintained
#ID ModBus:
1.1
#Start zoning:
1
Circuits
Luminaires
Installed:
summary of the ELC series luminaires registered on the device.
In failure:
summary of ELC series luminaires registered on the device that have a fault.
In brackets, indicate which of these luminaires are failing due to lack of communication.
Filter:
allows to filter the luminaires:
installed / Ok / in failure
Circuit:
select (with
<
and
>
) the number of circuits for which the luminaires will be
displayed (
not located
and 1 to 6)
Serial number:
select (with
<
and
>
) the various luminaires on the selected circuit.
Status:
displays the status of the ELC luminaire.
•
Communication loss:
the luminaire has not communicated with the device for less
than 24h.
•
Communication fail:
the luminaire has not communicated with the device for over 24h.
•
Lamp fail:
the luminaire has detected a fault in its light source.
•
Electronic fail:
the luminaire has detected a fault in its electronics. Requires repair
•
ok - Lamp on:
no faults and with the light source illuminated
•
ok - Lamp off:
no faults and with the light source off
Mode:
configure the operating mode of the ELC luminaire.
•
Maintained:
configure the luminaire as maintained.
•
Not maintained
: configure the luminaire as not maintained.
•
Switchable:
configure the luminaire as switchable (depending on the status of the
luminaire’s lum input status)
#ID ModBus:
allows assigning an identifier to the luminaires. The first digit is the circuit
number in which the luminaire is zoned and the second digit (from 1 to 32) is the
identifier of the luminaire within the circuit.
available only if the accessory is installed.