Contour Gen 2 Flex (Side Bend)

Installation Guide

www.gecurrent.com

© 2022 Current Lighting Solutions, LLC. All rights reserved. GE and the GE monogram are trademarks of the 

General Electric Company and are used under license. Information provided is subject to change without 

notice. All values are design or typical values when measured under laboratory conditions. 
SIGN299 (Rev 05/11/22)  DOC-2001572 

NOTE:  For linear long runs, center connection to the LED strip is recommended to minimize voltage drop. 

*GELP24-60U-GL minimum load = 15 ft. (4.57 m).

Maximum Loading per 24 VDC Class 2 Power Supply

Power Supply

GEXNFS32-1, GEXNFS65-1, GEXNFSRD-1, GEXNFSGL-1,  

GEXNFSBL-1, GEXNFSYG-1, GEXNFSRC-1

Rating per module

24VDC, 1.4W/ft. (Strip)

GEPS24-25U-NA, GEPS24-25-EU (CE only) 

Load shall not exceed 0.83A

15ft. (4.57 m)

GEPS24D-60U-GLX, *GELP24-60U-GL  

Load shall not exceed 2.5A

39 ft. (11.88 m)

GEPS24D-80U  

Load shall not exceed 3.3A

49ft. (14.93 m)

GEPS24-100U-GLX, GEPS24D-100U-NA,  

USVI-100024FE, USVI-100024FBA 

Load shall not exceed 4.0A

59ft. (17.98 m)

GEPS24-100U-GLX2, GEPS24-100U-TT 

Load shall not exceed 4.0A

62ft. (18.89 m)

GEPS24-200U-GLX2 

Load shall not exceed 4.0A per each (of 2) output channels

62ft. (18.89 m) per bank

124 ft. (37.78 m) per PS

GEPS24-300U-GLX2 

Load shall not exceed 4.0A per each (of 3) output channels

62ft. (18.89 m) per bank

186 ft. (56.67 m)  per PS

This product is intended solely for the use of non-residential signage lighting and is not intended for use in any other applications.

Conforms to the following standards:

Dismantling

At the end of life, the contained LED light source may be cut out using suitable wire cutters, removed from the mounting surface, 

then replaced per the cutting and installation instructions above, or dismantled and taken to a communal collecting point for 

environmentally friendly disposal in accordance with local regulations by a professional installer.

Electrical products must not be thrown out with domestic waste. They must be taken to a communal collecting point for environmentally friendly 

disposal in accordance with local regulations. Contact your local authorities or stockist for advice on recycling. The packaging material is recyclable. 

Dispose of the packaging in an environmentally friendly manner and make it available for the recyclable material collection-service.

Power Supply  

Wattage

18 AWG/0.82 mm

2

 

Supply Wire

16 AWG/1.31 mm

2

 

Supply Wire

14 AWG/2.08 mm

2

 

Supply Wire

12 AWG/3.31 mm

2

 

Supply Wire

25W

20 ft./6.1 m

60W,  80W, 100W,  

180W, 200W, 300W

20 ft./6.1 m

25 ft./7.6 m

35 ft./10.6 m

40 ft./12.1 m

Maximum Remote Mounting Distance from Driver Ouput

Summary of Contents for Contour Gen 2 Flex

Page 1: ...a versione italiana del manuale di installazione e sicurezza pu essere reperita nella seguente sezione https products gecurrent com eu led signage lighting LT Lietuvi k diegimo instrukcijos ir saugos...

Page 2: ...wiring or electrical components during kit installation RISQUE D INCENDIE OU DE CHOC LECTRIQUE L installation de l quipement de remplacement DEL exige Ia connaissance des syst mes lectriques pour ens...

Page 3: ...ade silicone Momentive RTV 6702 white RTV 6708 clear Silicone Rubber Adhesive Sealant Momentive RTV 162 White Silicone Rubber Adhesive Sealant Electrical Grade Dow Corning 3140 clear Non Corrosive Flo...

Page 4: ...dividing by 8 ft 2 44m to determine the required quantity of Contour Gen 2 Flex Refer to the Cutting Resolution Table on page 3 when cutting any Contour Gen 2 Flex section Do not use more than one su...

Page 5: ...rieur ou dans un environnement avec exposition l eau 6 7 For vertical or near vertical installations any cut end termination of a Contour piece shall reside at the top of the design 5 WARNING AVERTISS...

Page 6: ...om Planning First METHOD B Installing Light Engines With GEXNFMC 1 Flex Mounting Clip Install a Flex Mounting Clip using 6 M2 counter sink screws every 6 12 inches 152 305 mm on center until the end o...

Page 7: ...ion to the AC mains must be completed in an acceptable enclosure Power supply loading is described on page 9 Connect Power Supply WARNING AVERTISSEMENT RISK OF ELECTRICAL SHOCK Turn power OFF before i...

Page 8: ...e Contour Gen 2 Flex 8 Connect the DC output of the power supply to the LED modules using the Electrical Connections instructions above 9 Connect the power unit to the supply in accordance with the ap...

Page 9: ...124 ft 37 78 m per PS GEPS24 300U GLX2 Load shall not exceed 4 0A per each of 3 output channels 62ft 18 89 m per bank 186 ft 56 67 m per PS This product is intended solely for the use of non residenti...