background image

Contour Gen 2 Flex (Side Bend)

Installation Guide

3

Components and Tools Required

1

2

3

4

5

6

7

8

9

10

Contour Gen 2 Flex Side Bend Light Engine
GEXNFRL-1 Flex Rail or GEDSRLXX-3 Tetra SNAP Rail
GEXNFMC-1 Flex Mounting Clip
#6, #8 or #10 (M2, M3 or M4) self-drilling pan headed screws
#6 (M2) screws
Minimum 22 AWG (0.33mm

2

) tie-wire

24 Volt power supply
UL approved 18 AWG (0.82mm

2

) supply wire

UL approved 22-14 AWG (0.33-2.08mm

2

) twist-on wire connectors

GEXNFEC-1 Flex End Cap
Electrical grade silicone.
Examples of electrical grade silicone:

•  Momentive RTV 6702 (white) / RTV 6708 (clear) - Silicone Rubber Adhesive Sealant

•  Momentive RTV 162 (White) - Silicone Rubber Adhesive Sealant-Electrical Grade

•  Dow Corning 3140 (clear) - Non-Corrosive Flowable 

•  Dow Corning 3145 (clear or gray) - Non-Corrosive Non-flowable 

•  Dow Corning RTV 748 (white) - Non-Corrosive Sealant

Cutting Resolution Table

Light Engine Color

Cutting Resolution

Red, Red-Orange, 

Amber,Green, Blue, White

4 in. (101.6 mm)

1

2

Weather box GEXNWB2

Contour Light Guide connector
Contour Light Guide 90° inside corner
Contour Light Guide 90° outside corner
Contour Light Guide 90° planar corner

Optional / Required for Wet Locations

Optional 

12

13
14

16

15

3
4
5
6
7
8
9

10

11

11

16

12

13

14

15

100” (2.54 m)

95.4” (2.42 m)

Summary of Contents for Contour Gen 2 Flex

Page 1: ...a versione italiana del manuale di installazione e sicurezza pu essere reperita nella seguente sezione https products gecurrent com eu led signage lighting LT Lietuvi k diegimo instrukcijos ir saugos...

Page 2: ...wiring or electrical components during kit installation RISQUE D INCENDIE OU DE CHOC LECTRIQUE L installation de l quipement de remplacement DEL exige Ia connaissance des syst mes lectriques pour ens...

Page 3: ...ade silicone Momentive RTV 6702 white RTV 6708 clear Silicone Rubber Adhesive Sealant Momentive RTV 162 White Silicone Rubber Adhesive Sealant Electrical Grade Dow Corning 3140 clear Non Corrosive Flo...

Page 4: ...dividing by 8 ft 2 44m to determine the required quantity of Contour Gen 2 Flex Refer to the Cutting Resolution Table on page 3 when cutting any Contour Gen 2 Flex section Do not use more than one su...

Page 5: ...rieur ou dans un environnement avec exposition l eau 6 7 For vertical or near vertical installations any cut end termination of a Contour piece shall reside at the top of the design 5 WARNING AVERTISS...

Page 6: ...om Planning First METHOD B Installing Light Engines With GEXNFMC 1 Flex Mounting Clip Install a Flex Mounting Clip using 6 M2 counter sink screws every 6 12 inches 152 305 mm on center until the end o...

Page 7: ...ion to the AC mains must be completed in an acceptable enclosure Power supply loading is described on page 9 Connect Power Supply WARNING AVERTISSEMENT RISK OF ELECTRICAL SHOCK Turn power OFF before i...

Page 8: ...e Contour Gen 2 Flex 8 Connect the DC output of the power supply to the LED modules using the Electrical Connections instructions above 9 Connect the power unit to the supply in accordance with the ap...

Page 9: ...124 ft 37 78 m per PS GEPS24 300U GLX2 Load shall not exceed 4 0A per each of 3 output channels 62ft 18 89 m per bank 186 ft 56 67 m per PS This product is intended solely for the use of non residenti...

Reviews: