1.  (Existing Signs Only) Prior to installation, survey the site for information regarding power and accessibility inside 

and outside the building.  Ensure that the branch circuit supplying the existing transformer or ballast will be within 

the voltage ratings of the new LED power supply, and have a current rating not exceeding 20A, or that permitted by 

applicable local, state, or country electrical codes (whichever is less).   

2.  (Existing Signs Only) Remove the existing lighting equipment to be replaced, such as neon tubing or fluorescent 

tubes; and associated transformers and ballasts. Care should be taken not to break the existing neon or fluorescent 

tubes.  NOTE: Follow all federal and local regulations when disposing of neon tubing, fluorescent tubes, transformers 

and ballasts.

3.  (Existing Signs Only)  If removal of the existing lighting equipment eliminates the disconnect switch, as required by 

applicable local, state, or country electrical codes; a new disconnect switch must be installed.

4.  (Existing Signs Only) Repair and seal any unused openings in the electrical enclosure. Openings greater than 12.7-mm 

(1/2-in) diameter require a metal patch secured by screws or rivets and caulked with non-hardening caulk. Smaller 

openings may be sealed with non-hardening caulk.

5.  Using the layout guidelines above, determine required number of LED modules required to illuminate the sign.

6.  A 24VDC Class 2 Power Supply, as listed below, must be used with this retrofit kit. Determine the number of Power 

Supplies required to power the number of LED modules required to illuminate the sign, so as not to overload the Power 

Supply chosen.

7.  Follow Method A, B or C to mount the Contour Gen 2 Flex. 

8.  Connect the DC output of the power supply to the LED modules using the Electrical Connections instructions above.

9.  Connect the power unit to the supply in accordance with the applicable local, state, and country electrical codes, and 

the instructions found in the power supply installation guide.

10. If required, the disconnect switch shall be installed by qualified personnel, in accordance with applicable local, state, 

and country electrical codes.

Retrofit Instructions

Troubleshooting

Symptom

Condition

Solution

All LEDs are OFF

No AC input.

Attach AC input and/or check circuit breaker.

Incorrect wire attachment.

Check wire connection(s) at the Contour Gen 2 Flex LED light 

engine and power supply for improper connections or short 

circuits. Make sure you have positive to positive and negative to 

negative wire connections.

Some LEDs 

appear dim

Overload (maximum load exceeded).

Ensure the overall length of Contour LED Gen 2 Flex light engine 

does not exceed the maximum load as detailed in the Tetra 

Power Supply Installation Instructions.

Maximum recommended supply wire 

length exceeded.

Reduce the length of supply wire equal to or below the

recommended maximum.

Mixed Suffix Codes of LED light 

engine within an application. 

Make sure that all LED light engines have the same Suffix Code 

(Suffix Code is located on each packaging label).

Some of the 

sections are not 

illuminated

Incorrect wire attachment.

Check the wire connections at the Contour Gen 2 Flex LED light 

engine for improper connections. Make sure you have positive 

to positive and negative to negative wire connections. Check for 

improper cutting resolution locations (see table on Page 2).

Light/dark banding 

along a section

LED light engine flexed in the wrong 

direction or smaller than the minimum 

bend radius during installation.

Remove LED light engine and properly install.

Inspect and replace light engine if damaged.

Summary of Contents for Contour Gen 2 Flex

Page 1: ...a versione italiana del manuale di installazione e sicurezza pu essere reperita nella seguente sezione https products gecurrent com eu led signage lighting LT Lietuvi k diegimo instrukcijos ir saugos...

Page 2: ...wiring or electrical components during kit installation RISQUE D INCENDIE OU DE CHOC LECTRIQUE L installation de l quipement de remplacement DEL exige Ia connaissance des syst mes lectriques pour ens...

Page 3: ...ade silicone Momentive RTV 6702 white RTV 6708 clear Silicone Rubber Adhesive Sealant Momentive RTV 162 White Silicone Rubber Adhesive Sealant Electrical Grade Dow Corning 3140 clear Non Corrosive Flo...

Page 4: ...dividing by 8 ft 2 44m to determine the required quantity of Contour Gen 2 Flex Refer to the Cutting Resolution Table on page 3 when cutting any Contour Gen 2 Flex section Do not use more than one su...

Page 5: ...rieur ou dans un environnement avec exposition l eau 6 7 For vertical or near vertical installations any cut end termination of a Contour piece shall reside at the top of the design 5 WARNING AVERTISS...

Page 6: ...om Planning First METHOD B Installing Light Engines With GEXNFMC 1 Flex Mounting Clip Install a Flex Mounting Clip using 6 M2 counter sink screws every 6 12 inches 152 305 mm on center until the end o...

Page 7: ...ion to the AC mains must be completed in an acceptable enclosure Power supply loading is described on page 9 Connect Power Supply WARNING AVERTISSEMENT RISK OF ELECTRICAL SHOCK Turn power OFF before i...

Page 8: ...e Contour Gen 2 Flex 8 Connect the DC output of the power supply to the LED modules using the Electrical Connections instructions above 9 Connect the power unit to the supply in accordance with the ap...

Page 9: ...124 ft 37 78 m per PS GEPS24 300U GLX2 Load shall not exceed 4 0A per each of 3 output channels 62ft 18 89 m per bank 186 ft 56 67 m per PS This product is intended solely for the use of non residenti...