background image

Contour Gen 2 Flex (Side Bend)

Installation Guide

7

Push into clips

Insert wire connectors 

into weather box. Fill with 

electrical grade silicone and 

close box.

Secure the weather box using 

a #6 or #8 (M2 or M3) screw.

Power 

supply

Red (+)

Black or blue (–)

To Contour

Strip wires back 0.5 in. (13mm). 

Connect the red wire (+) 

from the LED strip to the red 

wire (+) of the power supply. 

Connect the black wire (-) 

from the LED strip to the black 

or blue wire (-) of the power 

supply.Grounding and bonding 

must be done in accordance 

with National Electrical Code 

(Article 600). See power supply 

instructions.

Run a wire from the power 

supply to a section of Contour. 

Power supply connection 

to the AC mains must be 

completed in an acceptable 

enclosure. Power supply 

loading is described on 

page 9.

Connect Power Supply

 

WARNING/AVERTISSEMENT

RISK OF ELECTRICAL SHOCK: Turn power OFF before inspection, installation or removal. 

RISQUES DE CHOC ÉLECTRIQUE: Coupez l’alimentation électrique avant d’inspecter, d’installer ou de déplacer le luminaire.

8

11

9

10

To power supply

Red (+)

Black or 

blue (–)

Weather box can be painted

Push each light 

engine segment 

into the clips. 

4

Insert wire connectors 

into weather box. Fill 

with electrical grade 

silicone and close 

box. Weather box can 

be mounted using #8 

(M3) screws.

To connect two 

light engines, first 

strip wire ends back 

0.5 in. (13mm). Then 

join wires together 

using twist-on wire 

connectors.

Secure light engine 

by twisting tie-wire 

around the mounting 

clip and light engine.

6

5

7

Weather 

box can be 

painted

+

Summary of Contents for Contour Gen 2 Flex

Page 1: ...a versione italiana del manuale di installazione e sicurezza pu essere reperita nella seguente sezione https products gecurrent com eu led signage lighting LT Lietuvi k diegimo instrukcijos ir saugos...

Page 2: ...wiring or electrical components during kit installation RISQUE D INCENDIE OU DE CHOC LECTRIQUE L installation de l quipement de remplacement DEL exige Ia connaissance des syst mes lectriques pour ens...

Page 3: ...ade silicone Momentive RTV 6702 white RTV 6708 clear Silicone Rubber Adhesive Sealant Momentive RTV 162 White Silicone Rubber Adhesive Sealant Electrical Grade Dow Corning 3140 clear Non Corrosive Flo...

Page 4: ...dividing by 8 ft 2 44m to determine the required quantity of Contour Gen 2 Flex Refer to the Cutting Resolution Table on page 3 when cutting any Contour Gen 2 Flex section Do not use more than one su...

Page 5: ...rieur ou dans un environnement avec exposition l eau 6 7 For vertical or near vertical installations any cut end termination of a Contour piece shall reside at the top of the design 5 WARNING AVERTISS...

Page 6: ...om Planning First METHOD B Installing Light Engines With GEXNFMC 1 Flex Mounting Clip Install a Flex Mounting Clip using 6 M2 counter sink screws every 6 12 inches 152 305 mm on center until the end o...

Page 7: ...ion to the AC mains must be completed in an acceptable enclosure Power supply loading is described on page 9 Connect Power Supply WARNING AVERTISSEMENT RISK OF ELECTRICAL SHOCK Turn power OFF before i...

Page 8: ...e Contour Gen 2 Flex 8 Connect the DC output of the power supply to the LED modules using the Electrical Connections instructions above 9 Connect the power unit to the supply in accordance with the ap...

Page 9: ...124 ft 37 78 m per PS GEPS24 300U GLX2 Load shall not exceed 4 0A per each of 3 output channels 62ft 18 89 m per bank 186 ft 56 67 m per PS This product is intended solely for the use of non residenti...