background image

Contour Gen 2 Flex (Side Bend)

Installation Guide

6

6-12 in. 

(152-305 mm)

Plan the layout by measuring the design 

layout and dividing by 8 ft . (2.44 m) 

to determine the required quantity 

of Contour Gen 2 Flex. Refer to the 

Cutting Resolution Table on page 3 

when cutting any Contour Gen 2 Flex 

section. 
Do not use more than one suffix 

code for each respective application, 

as mixing suffix codes may result in 

appearance variation. Suffix code can 

be found on the packaging label.
DO NOT bend the light engine to an inside radius that is tighter than 1 in. (25.4 mm).  
If you have questions about these instructions or your Contour application,  

contact support at [email protected]

Planning First

METHOD B - Installing Light Engines With GEXNFMC-1 Flex Mounting Clip

Install a Flex Mounting Clip, 

using #6 (M2) counter sink 

screws, every 6-12 inches 

(152-305 mm) on center until 

the end of the run is reached. 

Installation

Using the light engine final 

length, measure out the 

necessary length of Contour 

light engine so that it will 

extend at least 3/4 in. (19 mm) 

past the last mounting clip. If 

required, use a sharp cutting 

tool to cut through light engine.

For cut end, fill cap with 

electrical grade silicone and 

push end cap on the end to 

seal. Clean excess silicone.

1

2

3

 

WARNING / AVERTISSEMENT

RISK OF FIRE: DO NOT bend the light engine to an inside radius that is tighter than 1 in. (25.4 mm). 

RISQUE D’INCENDIE: Ne pas plier les modules DEL Contour avec un rayon de courbure inférieur à 1 pouce (25.4 mm).

Back bend

Side bend

Cut on marks only

Electrical grade 

silicone

Summary of Contents for Contour Gen 2 Flex

Page 1: ...a versione italiana del manuale di installazione e sicurezza pu essere reperita nella seguente sezione https products gecurrent com eu led signage lighting LT Lietuvi k diegimo instrukcijos ir saugos...

Page 2: ...wiring or electrical components during kit installation RISQUE D INCENDIE OU DE CHOC LECTRIQUE L installation de l quipement de remplacement DEL exige Ia connaissance des syst mes lectriques pour ens...

Page 3: ...ade silicone Momentive RTV 6702 white RTV 6708 clear Silicone Rubber Adhesive Sealant Momentive RTV 162 White Silicone Rubber Adhesive Sealant Electrical Grade Dow Corning 3140 clear Non Corrosive Flo...

Page 4: ...dividing by 8 ft 2 44m to determine the required quantity of Contour Gen 2 Flex Refer to the Cutting Resolution Table on page 3 when cutting any Contour Gen 2 Flex section Do not use more than one su...

Page 5: ...rieur ou dans un environnement avec exposition l eau 6 7 For vertical or near vertical installations any cut end termination of a Contour piece shall reside at the top of the design 5 WARNING AVERTISS...

Page 6: ...om Planning First METHOD B Installing Light Engines With GEXNFMC 1 Flex Mounting Clip Install a Flex Mounting Clip using 6 M2 counter sink screws every 6 12 inches 152 305 mm on center until the end o...

Page 7: ...ion to the AC mains must be completed in an acceptable enclosure Power supply loading is described on page 9 Connect Power Supply WARNING AVERTISSEMENT RISK OF ELECTRICAL SHOCK Turn power OFF before i...

Page 8: ...e Contour Gen 2 Flex 8 Connect the DC output of the power supply to the LED modules using the Electrical Connections instructions above 9 Connect the power unit to the supply in accordance with the ap...

Page 9: ...124 ft 37 78 m per PS GEPS24 300U GLX2 Load shall not exceed 4 0A per each of 3 output channels 62ft 18 89 m per bank 186 ft 56 67 m per PS This product is intended solely for the use of non residenti...