35000035C.FM  Page 1  Wednesday, January 3, 2001  9:33 AM

Содержание Destroyer X250

Страница 1: ...Destroyer X250 Punisher X250 user manual ...

Страница 2: ... Professional A S Denmark All rights reserved No part of this manual may be reproduced in any form or by any means without permission in writing from Martin Professional A S Denmark Printed in Denmark P N 35000035 Rev C ...

Страница 3: ...are programmable from any standard DMX 512 controller using a single or multi channel protocol Alternatively the Destroyer and Punisher can be directly triggered from a music source as stand alone units In addition the Destroyer can run several units in master slave configuration F EATURES Multiple rotating beams 12 pattern gobo wheel 7 with color and 5 white 24 V 250 W halogen lamp Dichroic color...

Страница 4: ...ce to a qualified technician Never operate the fixture with missing or damaged lenses and or covers To protect yourself and others from burns and fire Never attempt to bypass the thermostatic switch or fuses Always replace defective fuses with ones of the specified type and rating Keep all combustible materials at least 0 1 meters 4 inches away from the fixture Keep flammable materials well away f...

Страница 5: ...level verify that the structure can hold at least 10 times the weight of all installed devices Verify that all external covers and rigging hardware are securely fastened and use an approved means of secondary attachment such as a safety cable Block access below the work area whenever installing or removing the fixture ...

Страница 6: ... Do not install any other lamp Warning Allow the unit to cool for 15 minutes before handling 1 Remove the 2 screws from the lamp access plate on the bottom of the unit 2 Loosen the thumbscrew and pull back on the lamp socket reflector assembly until the assembly is free of its mounting plate Remove the lamp assembly 3 Hold the new lamp in a cloth to avoid contaminating it with oils from your finge...

Страница 7: ...r supply rewire the unit as follows Important To prevent damage the RED wire must be connected to an outside pin as shown 1 Disconnect the fixture from AC power Remove the top cover from the unit by unscrewing the 4 screws that hold it in place 2 Locate and disconnect the plug with red yellow and blue wires at the top right corner of the printed circuit board as seen from the back of the unit 3 To...

Страница 8: ...iliary equipment etc 2 If hanging the fixture with a rigging clamp verify that the clamp is undamaged and is designed for the fixture s weight Bolt the clamp securely to the bracket with a grade 8 8 minimum M12 bolt and lock nut or as recommended by the clamp manufacturer through the clamp hole in the mounting bracket 3 If permanently installing the fixture verify that the hardware not included an...

Страница 9: ...le adaptor cable P N 11820005 2 Lead the data cable from the controller to the first fixture Plug the cable into the fixture s data input 3 Connect the output of the fixture closest to the controller to the input of the next fixture If connecting two fixtures with reversed polarity on pins 2 and 3 insert a phase reversing cable between the two fixtures 4 Continue connecting fixtures output to inpu...

Страница 10: ... the pin ON for 1 channel operation of OFF for multi channel operation A D D R E S S S E TT I N G Use the first 8 DIP switches to set the DMX address the first DMX channel on which the Destroyer Punisher responds to the controller to any value between 1 and 255 The address is the sum of the values for each individual DIP switch that is ON Important DIP switch 10 must be flipped ON when using the D...

Страница 11: ... 7 39 71 103 135 167 199 231 0 0 0 1 0 8 40 72 104 136 168 200 232 1 0 0 1 0 9 41 73 105 137 169 201 233 0 1 0 1 0 10 42 74 106 138 170 202 234 1 1 0 1 0 11 43 75 107 139 171 203 235 0 0 1 1 0 12 44 76 108 140 172 204 236 1 0 1 1 0 13 45 77 109 141 173 205 237 0 1 1 1 0 14 46 78 110 142 174 206 238 1 1 1 1 0 15 47 79 111 143 175 207 239 0 0 0 0 1 16 48 80 112 144 176 208 240 1 0 0 0 1 17 49 81 113...

Страница 12: ...ll perform exactly the same when set to DMX address 1 Important To prevent damage to the electronic circuitry one and only one fixture may be set as master DIP switch 10 OFF 1 Disconnect all fixtures from AC power 2 On the master unit set DIP switch 10 OFF 3 On all slave units set DIP switch 1 and 10 ON 4 Insert a 120Ω female XLR termination plug P N 91613018 in the DMX input socket of the master ...

Страница 13: ...riggered triggers when DMX level crosses 195 3 0 91 92 98 99 189 190 231 232 255 Parabol Speed The rotation time is equal to the trigger decay if trigger mode is set to music or controller Rotation CW fast slow Stop Rotation CCW slow fast Random CW CCW slow music controller triggered Random CW CCW fast music controller triggered 4 0 4 5 252 253 255 Trigger Decay 0 seconds 0 2 to 9 9 seconds Random...

Страница 14: ...4 Position 5 Position 6 Position 7 Position 8 Position 9 Position 10 Position 11 Position 12 No effect Random music controller triggered 6 0 4 5 252 253 255 Shake Punisher only Off Slow fast Random music controller triggered Channel DMX Value Effect 1 0 50 51 101 102 152 153 203 204 255 Blackout Slow random action Medium random action Fast random action Random speed and action DMX Channel DMX Valu...

Страница 15: ...e unit Ensure that all units are addressed in compliance with the controller configuration Unit not powered on Power on unit One or more units are set to master i e DIP switch 10 OFF Set DIP switch 10 ON One of the units is defective and disturbs the data transmission on the link By pass one unit at a time until normal operation is regained Do this by unplugging the XLR in and out connectors and t...

Страница 16: ... W 2 3 A 120 V Input socket 3 prong IEC male socket Input 230 245 V model 230 245 V 50 60Hz Input 110 120 V model 110 125 V 50 60Hz Primary fuse 230 245 V model 2 5 AT 250 V P N 05020010 Primary fuse 110 120 V model 5 0 AT 250 V P N 05020018 I N S T A L L A T IO N Minimum distance to combustible materials 0 1 m 4 in Minimum distance to illuminated surfaces 0 3 m 12 in Minimum clearance around fan ...