background image

English

14

• When the air conditioner is changed over 

to the HEATING OPERATION after the 
DEFROST OPERATION and in the 
DEFROST OPERATION.

Moisture generated by defrost becomes 
steam and exists.
When the remote controller display shows 
"

", DEFROST OPERATION is being 

used.

VII. NOISE OF AIR CONDITIONERS

• A ringing sound after the indoor unit is 

started.

This sound is generated when the motors for 
driving the horizontal blades are working.
It will quiet down after about a minute.

• A low continuous flow "Shuh" sound 

which is heard when the air conditioner is 
in the COOLING or DEFROST 
OPERATION or a trickling sound which is 
heard when the air conditioner is in the 
DEFROST OPERATION.

This is the sound of refrigerant gas flowing 
through both indoor and outdoor units.

• A "Shuh" sound which is heard at the 

start or immediately after the stop of 
operation or which is heard at the start or 
immediately after the stop of the 
DEFROST OPERATION. 

This is the noise of refrigerant caused by flow 
stop and flow change.
During the HEATING OPERATION, the air 
conditioner switches to the DEFROST 
OPERATION automatically. 
The remote controller shows "

".

After maximum 10 minutes, the air 
conditioner returns to its original operation.

• A continuous flow "Shah" sound is heard 

when the air conditioner is in the 
COOLING OPERATION or at a stop.

The noise is heard when the drain pump is in 
operation.
Liquid removed from the indoor air during the 
COOLING OPERATION is discharged.

• A "Pishi-pishi" squeaking sound is heard 

when the air conditioner is in operation or 
after the stop of operation.

Expansion and contraction of resin parts 
caused by temperature change makes this 
noise.

VIII. DUST FROM THE INDOOR UNITS

• Dust may blow out from the unit after 

starting operation from long resting time.

Dust absorbed by the unit blows out.

IX. THE INDOOR UNITS GIVE OFF ODORS

• During operation

The unit absorbs the smell of rooms, 
furniture, cigarettes, etc., and then emits 
them.
If odor is a concern, set the fan speed to no 
airflow when the indoor temperature reaches 
the set temperature.
For details, contact your local dealer.

X. THE AIR CONDITIONER DOES NOT COOL 

EFFECTIVELY

• The air conditioner is operating in 

PROGRAM DRY OPERATION.

This is because program dry mode operates 
so that the indoor temperature decreases as 
little as possible.
Lower the indoor temperature using the 
COOLING OPERATION, and then use the 
PROGRAM DRY OPERATION.
(Refer to "

CHARACTERISTICS OF THE 

PROGRAM DRY OPERATION

" on page 7.)

• Read through characteristics of the 

COOLING OPERATION, characteristics of 
the HEATING OPERATION, and 
characteristics of the PROGRAM DRY 
OPERATION on page 7.

10. TROUBLESHOOTING

Please check before requesting a service.

1. If the air conditioner does not operate at all.

Check if fuse has blown.
Turn off the power supply.

Check if the power circuit breaker is blown.
If the tab of power circuit breaker is in the OFF 
position, turn the power on with the power 
circuit breaker switch.
If the tab of power circuit breaker is in the trip 
position, do not turn the power on with the 
power circuit breaker switch.
Contact your local dealer.

Check if there is a power failure.
Wait until power is restored. If power failure 
occurs during operation, the air conditioner 
automatically restarts immediately after the 
power supply recovers.

1

Power circuit breaker (earth leakage breaker)

2

Tab

3

Trip position

ON

OFF

2

3

1

4PEN465543-1D.book  Page 14  Monday, February 25, 2019  9:26 AM

Summary of Contents for RZAG100

Page 1: ...OPERATION MANUAL FUA71AVEB9 FUA100AVEB9 FUA125AVEB9 Split system air conditioners 4PEN465543 1D book Page 1 Monday February 25 2019 9 26 AM...

Page 2: ...can be used by children aged from 8 years and above and persons with reduced physical sensory or mental capabilities or lack of experience and knowledge if they have been given supervision or instruct...

Page 3: ...a utility piping lightning conductor or telephone earth lead Imperfect earthing may result in electric shocks or a fire A high surge current from lightning or other sources may cause damage to the ai...

Page 4: ...animals or works of art as this may adversely affect the performance quality and or longevity of the object concerned Do not install the air conditioner at any place where there is a danger of flammab...

Page 5: ...ontroller when used as simulta neous operation A Pair system or simultaneous operation system B Multi system 1 Unit with remote controller 2 Unit without remote controller when used as simulta neous o...

Page 6: ...ure The setting temperature range of the remote controller is 16 C 32 C depends on heating cooling mode 4 INSTALLATION SITE Regarding places for installation Is the air conditioner installed at a well...

Page 7: ...your system type To protect the air conditioner turn on the main power switch 6 hours before operation Do not shut off the power supply during seasonal use of the air conditioner This is required in...

Page 8: ...irection becomes horizontal The remote controller displays the fan speed and airflow direction that are set CHARACTERISTICS OF THE PROGRAM DRY OPERATION This operation lowers the humidity without lowe...

Page 9: ...r operates Prevent direct sunlight from the window by using curtains or blinds during the COOLING OPERATION Keep doors and windows closed If the doors and windows remain open room air will flow out an...

Page 10: ...nstable it may cause injuries due to fall and stumbling NOTE Do not remove the air filter unless for cleaning It may cause failure Do not attach substance such as paper towels other than the specified...

Page 11: ...e closing the suction grille confirm if the strap is not sticking out from the side of the suction grille If the air filter is extremely contaminated wash it with neutral detergent using a soft brush...

Page 12: ...HAT TO DO WHEN START UP AFTER A LONG STOP Confirm the following Check that the air inlet and outlet of indoor and outdoor unit are not blocked Remove any obstacle Obstacles decrease the fan speed and...

Page 13: ...off the power circuit breaker during seasonal use of the HEATING OPERATION I THE AIR CONDITIONER DOES NOT OPERATE The air conditioner does not restart immediately after the ON OFF button is pressed T...

Page 14: ...t swing when the remote controller displays the swing operation HEATING OPERATION This is because the airflow direction is controlled so it is horizontal direction after the operation starts or when t...

Page 15: ...by temperature change makes this noise VIII DUST FROM THE INDOOR UNITS Dust may blow out from the unit after starting operation from long resting time Dust absorbed by the unit blows out IX THE INDOOR...

Page 16: ...to an appropriate temperature fan speed and airflow direction Check if the airflow direction is not proper Set to an appropriate temperature fan speed and airflow direction Check if the doors or the...

Page 17: ...local and national legislation Units and waste batteries must be treated at a specialized treatment facility for re use recycling and recovery By ensuring correct disposal you will help to prevent pot...

Page 18: ...4P465543 1D 2019 02 Copyright 2017 Daikin 4PEN465543 1D book Page 1 Monday February 25 2019 9 26 AM...

Reviews: