background image

English

6

• Is a snow protection measure taken?

For details, consult your local dealer about snow 
protection hoods, etc.

Regarding wiring

• All wiring must be performed by an qualified 

personnel.

To do wiring, ask your local dealer. Never do it by 
yourself.

• Make sure that a separate power supply 

circuit is provided for this air conditioner and 
that all electrical work is carried out by 
qualified personnel according to local laws 
and regulations.

Pay attention to running noises, too

• Are the following places selected?

a. A place that can sufficiently withstand the mass 

of the air conditioner with less running noises 
and vibrations.

b. A place where the hot wind discharged from the 

air outlet of the outdoor unit and the running 
noises do not cause a nuisance to neighbours.

• Are you sure that there are no obstacles near 

the air outlet of the outdoor unit?

Such obstacles may result in declined 
performance and increased running noises.

• If abnormal noises occur in use, stop the 

operation of the air conditioner, consult your 
local dealer.

Regarding drainage of drain piping

• Is the drain piping carried out properly to 

ensure complete drainage?

If drain piping is not carried out properly, dirt and 
debris may be accumulated in the drain piping 
and cause water leakage. If it occurs, stop the air 
conditioner and consult with your local dealer for 
assistance.

WARNING

Prevent hazards due to inadvertent resetting of the 
thermal cut-out: this appliance MUST NOT be supplied 
through an external switching device, such as a timer, 
or connected to a circuit that is regularly turned ON 
and OFF by the utility.

5. OPERATION PROCEDURE

Read the installation manual attached to the outdoor 
unit and manual for remote controller.
Operating procedure varies with heat pump and 
cooling only type. Contact your dealer to confirm 
your system type.

To protect the air conditioner, turn on the main 
power switch 6 hours before operation.

Do not shut off the power supply during seasonal 
use of the air conditioner.
This is required in order to activate the air 
conditioner smoothly.

If the main power supply is turned off during 
operation, operation will restart automatically 
after the power turns back on again.

6. OPERATION CHARACTERISTICS

CHARACTERISTICS OF THE COOLING 
OPERATION (COOLING OPERATION AND 
AUTOMATIC COOLING OPERATION)

If the COOLING OPERATION is used when the 
indoor temperature is low, frost adheres to the 
heat exchanger of the indoor unit.
This can decrease the cooling capacity.
In this case, the air conditioner automatically 
switches to the DEFROST OPERATION for a 
while.
During the DEFROST OPERATION, the low fan 
speed or a gentle wind is used to prevent the 
discharge of melt water.
(The remote controller displays the fan speed that 
is set.)

When the outdoor temperature is high, it takes 
some time until the indoor temperature reaches 
the set temperature.

CHARACTERISTICS OF THE HEATING 
OPERATION (HEATING OPERATION AND 
AUTOMATIC HEATING OPERATION)

START OF OPERATION

It generally takes a longer time for indoor 
temperature of the HEATING OPERATION to 
reach the set temperature compared to the 
COOLING OPERATION.
It is advisable to start operation in advance using 
the TIMER OPERATION.

Perform the following operation to prevent 
heating capacity decrease and discharge of cool 
air.

AT THE START OF OPERATION AND AFTER 
THE DEFROST OPERATION

A warm air circulating system is employed, and 
therefore it takes some time until the entire room 
is warmed up after the start of operation.

The indoor fan runs to discharge a gentle wind 
automatically until the temperature inside the air 
conditioner reaches a certain level. At this time, 
the remote controller displays "

". Leave it 

as it stands and wait for a while.
(The remote controller displays the fan speed that 
is set.)

4PEN465543-1D.book  Page 6  Monday, February 25, 2019  9:26 AM

Summary of Contents for RZAG100

Page 1: ...OPERATION MANUAL FUA71AVEB9 FUA100AVEB9 FUA125AVEB9 Split system air conditioners 4PEN465543 1D book Page 1 Monday February 25 2019 9 26 AM...

Page 2: ...can be used by children aged from 8 years and above and persons with reduced physical sensory or mental capabilities or lack of experience and knowledge if they have been given supervision or instruct...

Page 3: ...a utility piping lightning conductor or telephone earth lead Imperfect earthing may result in electric shocks or a fire A high surge current from lightning or other sources may cause damage to the ai...

Page 4: ...animals or works of art as this may adversely affect the performance quality and or longevity of the object concerned Do not install the air conditioner at any place where there is a danger of flammab...

Page 5: ...ontroller when used as simulta neous operation A Pair system or simultaneous operation system B Multi system 1 Unit with remote controller 2 Unit without remote controller when used as simulta neous o...

Page 6: ...ure The setting temperature range of the remote controller is 16 C 32 C depends on heating cooling mode 4 INSTALLATION SITE Regarding places for installation Is the air conditioner installed at a well...

Page 7: ...your system type To protect the air conditioner turn on the main power switch 6 hours before operation Do not shut off the power supply during seasonal use of the air conditioner This is required in...

Page 8: ...irection becomes horizontal The remote controller displays the fan speed and airflow direction that are set CHARACTERISTICS OF THE PROGRAM DRY OPERATION This operation lowers the humidity without lowe...

Page 9: ...r operates Prevent direct sunlight from the window by using curtains or blinds during the COOLING OPERATION Keep doors and windows closed If the doors and windows remain open room air will flow out an...

Page 10: ...nstable it may cause injuries due to fall and stumbling NOTE Do not remove the air filter unless for cleaning It may cause failure Do not attach substance such as paper towels other than the specified...

Page 11: ...e closing the suction grille confirm if the strap is not sticking out from the side of the suction grille If the air filter is extremely contaminated wash it with neutral detergent using a soft brush...

Page 12: ...HAT TO DO WHEN START UP AFTER A LONG STOP Confirm the following Check that the air inlet and outlet of indoor and outdoor unit are not blocked Remove any obstacle Obstacles decrease the fan speed and...

Page 13: ...off the power circuit breaker during seasonal use of the HEATING OPERATION I THE AIR CONDITIONER DOES NOT OPERATE The air conditioner does not restart immediately after the ON OFF button is pressed T...

Page 14: ...t swing when the remote controller displays the swing operation HEATING OPERATION This is because the airflow direction is controlled so it is horizontal direction after the operation starts or when t...

Page 15: ...by temperature change makes this noise VIII DUST FROM THE INDOOR UNITS Dust may blow out from the unit after starting operation from long resting time Dust absorbed by the unit blows out IX THE INDOOR...

Page 16: ...to an appropriate temperature fan speed and airflow direction Check if the airflow direction is not proper Set to an appropriate temperature fan speed and airflow direction Check if the doors or the...

Page 17: ...local and national legislation Units and waste batteries must be treated at a specialized treatment facility for re use recycling and recovery By ensuring correct disposal you will help to prevent pot...

Page 18: ...4P465543 1D 2019 02 Copyright 2017 Daikin 4PEN465543 1D book Page 1 Monday February 25 2019 9 26 AM...

Reviews: